6 Technical Specifications
Specifications
Parameter
Value
Comment
Accuracy ±2%
Resolution ±1%
Number of Tank Types
16
Fuel, Fresh Water, Waste Water, Live Well, Oil, etc.
Number of Tanks per Tank Type
16
16 Tanks per Tank Type Numbered 0-15
Maximum Tank Depth
40” (1.02m)
Minimum Depth Reading
2” (5.08cm) Sensor Deadband
Support for Irregularly Shaped
Tanks
Yes
Can be Calibrated for any Shape Tank
Programmable Tank Capacity
Yes
Allows Displays to Calculate Amount Remaining
Maximum Tank Angle
6°
Without focus tube
15°
With focus tube
Certifications
Parameter
Comment
NMEA 2000
Level B+
Maritime Navigation and Radiocommunication Equipment & Systems
Tested to IEC 60945
FCC and CE Mark
Electromagnetic Compatibility
NMEA 2000
®
Parameter Group Numbers (PGNs) - See Appendix A for Details
Description
PGN #
PGN Name
Default Rate
Periodic Data PGNs
127505
Fluid Level
0.4 Times/Second
Response to Requested PGNs
126464
PGN List (Transmit and Receive)
N/A
126996 Product
Information
N/A
126998 Configuration
Information
N/A
Protocol PGNs
059392
ISO Acknowledge
N/A
059904 ISO
Request
N/A
060928 ISO
Address
Claim
N/A
065240 ISO
Address
Command
N/A
126208 NMEA
N/A
Electrical
Parameter
Value
Comment
Operating Voltage
9 to 16 Volts
DC Voltage
Power Consumption
<100mA
Average Current Drain
Load Equivalence Number (LEN)
2
NMEA 2000
®
Spec. (1LEN = 50mA)
Reverse Battery Protection
Yes
Indefinitely
Load Dump Protection
Yes
Energy Rated per SAE J1113