The convertible lower element – Maytag HRE11282T User Manual

Page 9

background image

9

supply or hardware stores. Follow manufacturers instructions
for installation of the valves. Before changing the factory setting
on the thermostat, read the “Temperature Regulation” section
in this manual.

FIGURE 8

WATER HEATERS EVENTUALLY LEAK: Installation of the water
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water will not cause
damage to the structure. For this reason, it is not advisable to
install the water heater in an attic or upper floor. When such
locations cannot be avoided, a suitable drain pan should be
installed under the water heater. Drain pans are available at
your local hardware store. Such a drain pan must have a
minimum length and width of at least 1 3/4 inches greater than
the water heater dimensions and must be piped to an
adequate drain.

INSTALLATION IN RESIDENTIAL GARAGES: The water heater
must be located and/or protected so it is not subject to physical
damage by a moving vehicle.

The location selection must provide adequate clearances
for servicing and proper operation of the water heater.

The Convertible Lower Element

The Upper Element, is a conventional 3800 watt element which
only operates at its rated wattage on 240 volts. (See rating
plate on the water heater).

The Lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.

Read and follow water heater warnings and instructions. If
after reading these instructions in this manual, you do not
understand any portion, call Maytag Customer Service at
1-800-788-8899 for an authorized sevicer.

Before making the conversion to 5500 watts, check the (1)
power supply . . . must be 240 volts, (2) wiring . . . 10 gauge
AWG @ Type TW, 60°C or equivalent, and (3) Circuit breakers
or fusing . . .capable of 30 amp loading. Also, the installation
must conform with this manual, local codes and electric utility
rules. Failure to comply can result in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE.

NOTE: Whether or not the element conversion is made the
model rating plate must be marked. Using a hard point ink
pen, check the appropriate block within the model rating plate,
which is located adjacent to the lower access panel.