beautypg.com

Cust – Maytag HRE11282T User Manual

Page 5

background image

5

Thank You for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble
free service. It is strongly suggested that this new water heater
be professionally installed, call Maytag Customer Service
at 1-800-788-8899 for recommended installers.

Abbreviations Found In This Instruction Manual:

UL – Underwriters Laboratories, Inc.

NEC – National Electrical Code

ANSI – American National Standards Institute

Read the “General Safety” section, page 3 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.

This manual contains instructions for the installation,
operation, and maintenance of this electric water heater. It
also contains warnings throughout the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING
TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the

absence of Local Codes, with the current edition of the
NEC - National Electrical Code NFPA 70. This publication is
available from your local government or public library or
electric company or by writing Underwriters Laboratories
Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do
not understand any portion of the instructions, call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.

Carefully plan the place where you are going to put the water
heater. Correct electrical wiring and connections are very
important in preventing death from possible electrical shock
and fires.

Examine the location to ensure the water heater complies with
the “Locating the New Water Heater” section.

For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from the California
office of the State Architect, 400 P Street, Sacramento,
CA 95814.

Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00. In the
Commonwealth of Massachusetts, this product must be
installed by a licensed plumber or gasfitter.

CUST

CUST

CUST

CUST

CUSTOMER INFORMA

OMER INFORMA

OMER INFORMA

OMER INFORMA

OMER INFORMATION

TION

TION

TION

TION

PRODUCT SPECIFICA

PRODUCT SPECIFICA

PRODUCT SPECIFICA

PRODUCT SPECIFICA

PRODUCT SPECIFICATIONS

TIONS

TIONS

TIONS

TIONS

MAXIMUM

FUSE OR
CIRCUIT

MINIMUM

BREAKER

MODEL

WIRE SIZE

SIZE

NUMBER

GALS

DIA.

HEIGHT

UPPER LOWER

UPPER

(GAUGE)

(AMPS)

HRE11240S

40

22.5

47

17.3

17.3

25

3800

3800

5500

12

20

HRE41240S

40

22.5

47

17.3

17.3

25

3800

3800

5500

10

30

HRE11250S

50

24

50

17.3

17.3

25

3800

3800

5500

12

20

HRE41250S

50

24

50

17.3

17.3

25

3800

3800

5500

10

30

HRE11250T

50

22.5

57

17.3

17.3

25

3800

3800

5500

12

20

HRE41250T

50

22.5

57

17.3

17.3

25

3800

3800

5500

10

30

HRE11282T

80

26

62

17.3

17.3

25

3800

3800

5500

12

20

HRE41282T

80

26

62

17.3

17.3

25

3800

3800

5500

10

30

** Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical

code.

LOWER

ELEMENT

WATTAGE

@240 VOLTS

DIMENSIONS

IN INCHES

RECOVERY RATE

IN GALLONS

PER HOUR

@ 90°F RISE

TANK

CAPACITY

This manual is related to the following products: