Optional Backsplash Accessories

The range requires a 12" minimum clearance to a vertical combustible

surface at the rear. A backsplash is required for installations with

less than 12" clearance. The following backsplash accessories are

available, or a custom, non-combustible backsplash can be used.
Backsplashes: Order one with a 36"-wide range

zX12B36hss–12" backsplash

zX22B36hss– 22" backsplash with warming shelf

Backsplash with Warming shelf

All Monogram Professional Wall-Mounted Hoods feature infrared

warming lights. The 22"-high warming shelf is a perfect complement

when installed with the tapered or straight-sided hoods.
If you choose to install this range with a Restaurant-Style

Professional Hood (ZV36RSFSS), no additional accessories are

required. These hoods are shipped with a stainless steel

backsplash and warming shelf.

side View with a Backsplash

Electrical Requirements

Ranges must be supplied with 208/240V, 60Hz, and connected to

an individual, properly grounded branch circuit protected by a circuit

breaker or time-delay fuse. Install a 30-amp circuit for 36" ranges. The

receptacle must be a NEMA 14-50R device to accept the four-prong

plug on the range.

zdp36n4dhss

(natural Gas)

zdp36l4dhss

(liquid propane)

– GE Monogram 36" dual Fuel professional Range with

4 Burners and Griddle

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

GEAppliances.com or call GE Answer Center

®

service, 800.626.2000.

Listed by

Underwriters

Laboratories

Backguard

36" Min.

to

Combustibles

0" Clearance

12" Min. to Combustibles or

0" Min. to Combustibles

with 12" or 22" Backsplash

Gas supply

• Natural gas models are designed to operate at 5" water column

pressure. A regulator is required at the natural gas source to

provide maximum of 7" water pressure to the range regulator.

• The liquid propane models are designed to operate at 10" water

column pressure. A regulator is required at the LP source to provide

maximum of 14" water pressure to the range regulator.

4"

4"

4"

12"

12"

Gas

Supply

36"

1-1/2"

4"

Electric

Supply

Locate gas and

electric as shown

specification Revised 3/08