UV-C Light Bulb & Filter

Ultraviolet light technology, the same technology used in hospitals and commercial settings

for sanitizing, is capable of eradicating mircoorganisms, mold spores and viral contaminants

from the air.
It is recommended that you leave the Germ Guardian UV-C Air Sanitizer running continuously.

A replaceable 9-watt UV-C light bulb is guaranteed to last 8,000 hours - almost a full year of

continuous use. A filter that helps reduce odors is also in the product and should be replaced

once a year. Over time, with use, the 9-watt UV-C bulb will lose some intensity (about 15% at

9,000 hours), therefore it is suggested that the light bulb be replaced once every year. You will

know when to change the 9-watt light bulb when it continuously flickers or changes color. The

replacement bulb and filter come in one package.
To reorder bulb & filter pack EV9LB or EV9LBL, please call Customer Service 1.866.603.5900 or

go to www.germguardian.com.

Use of the Germ Guardian Unit

When the Germ Guardian is turned on you will see two rings of blue light that let you know it is

working. The Germ Guardian UV-C Room Air Sanitizer can process 1,380 cubic feet of air per hour

and is effective in almost any size room. Depending on dust conditions and build-up, you may need

to occasionally clean the bulb and cylinder with a soft, dry cloth. This product is safe for use around

children and pets, and is cool to the touch.

WARNING: Electrical Shock

UNDER NO CIRCUMSTANCES ShOULD YOU CLEAN ThE BULB, BULB hOLDER OR

CYLINDER WITh WATER OR WET SOLUTIONS. ThIS COULD CAUSE ELECTRICAL ShOCk.

Directions for Use

Plug unit into a 120V AC electrical outlet.

1.

Switch the power button to the ON position.

2.

A small red light should light up on the switch.
Use the knob next to the power switch to

3.

adjust the fan speed. Turn the knob

clockwise for increased air flow.
For best results continuous operation

4.

is recommended.

NOTE: ThE GERM GUARDIAN UNIT CONTAINS NO SERVICEABLE PARTS ExCEPT ITS

UV-C BULB AND FILTER. ThE BULB AND FILTER MAY BE REMOVED FOR REPLACEMENT.

Replacing and Cleaning the UV-C Bulb & Filter

Turn off the unit and unplug it from

1.

the electrical outlet.

Using a small phillips head screwdriver, loosen and

2.

remove the phillips screw located at the top of the

unit, directly above the power cord.

Remove the top cap by lifting its side near the

3.

screw hole, then gently push the cap in the

opposite direction.

As the cap loosens, you may lift it off.

4.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: Electrical Shock

ALWAYS UNPLUG ThE GERM GUARDIAN UNIT

FROM ELECTRICAL OUTLET WhEN SERVICING.