GE JKP25SH User Manual
Jkp25sh – ge® 27" built-in single oven, Ge appliances, 27" built-in single oven dimensions (in inches)
GE Appliances
JKP25SH – GE® 27" Built-In Single Oven
Installation Information: Before installing, consult installation
instructions packed with product for current dimensional data.
27" Built-In Single Oven Dimensions (in inches)
Specification Revised 7/05
320431
2" x 4"
or equiv.
runners
B MIN.
C MIN.
Conduit 48-1/2" long
6015 Built-in Single Oven
(Pub. 1-G003 pg. 107) April 28, 1993
32-1/2
D
10
A
Allow 3/4"
for overlap
over all edges
of cutout
Locate
junction box
either 5" MIN.
below cutout
floor or 44"
MIN. above
cutout floor
Minimum
cutout location
from floor
(Minimum 15-5/8"
from floor when
installed below built-in
microwave oven)
E
G
F
20
Note: These ovens are not
approved for stackable or
side-by-side installations.
Note: These ovens can be
installed side-by-side with no
less than 30" distance between
center-to-center of each oven.
Note: Cabinets installed adjacent to wall ovens
must have an adhesion spec of at least a 194°F
temperature rating.
Note: For 27" built-in single ovens, if marks,
blemishes or the cutout opening is visible
above the installed oven, it may be necessary
to add wood shims under the runners and front
trim until the marks or openings are covered.
Cabinet
27"
A – Cabinet Width Required
27" min.
B – Minimum Cabinet Depth
23-5/8"
C – Opening Width
25" min. - 25-1/4 max.
D – Opening Height
27-5/8" min. - 28-1/8 max.
Oven
E – Overall Depth
23-5/8"
w/o trim
28-1/4"
F – Overall Height with trim
29"
G – Overall Width
26-5/8"
CL
Suitable
bracing
to support
runners
18"
Over centerline
of cabinet
2" x 4" or
equivalent
runners
(Must support 275 lbs.)
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
KW Rating
240V
3.4
208V
2.6
Breaker Size
240V
20 Amps
208V
20 Amps
Electric wall ovens are not approved for installation with a plug and receptacle.
They must be hard wired in accordance with installation instructions.