beautypg.com

See charge battery – Gravely 988100-GR1336FX User Manual

Page 22

background image

GB - 22

3. Repeat for each inspection slot.

To adjust:

1. If necessary, loosen gap adjustment nuts until a

.005" feeler gauge fits between armature and
rotor.

2. Slide a .012" feeler gauge between armature and

rotor.

3. Tighten gap adjustment nut until there is slight

contact on feeler gauge.

4. Repeat steps 1 – 3 at each inspection slot.

NOTE: Adjust air gap as evenly as possible.

5. Start unit, engage and disengage PTO.

6. Shut off unit.

7. Recheck air gap and adjust if needed.

BATTERY (988104)

Unit comes equipped with a maintenance-free battery
that requires no regular maintenance except cleaning
the terminals. See Check Battery (988104) on page 18.

Charge Battery

Battery Electrolyte First Aid

External Contact: Flush with water.

Eyes: Flush with water for at least 15 minutes
and get medical attention immediately!

Internal Contact: Drink large quantities of water.
Follow with Milk of Magnesia, beaten egg or
vegetable oil. Get medical attention immediately!
DO NOT induce vomiting!

IMPORTANT: DO NOT fast charge. Charging at a
higher rate will damage or destroy battery.

IMPORTANT: ONLY use an automatic charger
designed for use with your battery. ALWAYS follow
information provided on battery and battery charger.
Contact battery and charger manufacturers for detailed
instructions.

1. Remove battery cover.

2. Disconnect negative (–) cable first, then positive

(+) cable (Figure 15).

3. Remove battery.

4. Place battery on bench or other well-ventilated

area.

5. Connect positive (+) lead of charger to

positive (+) terminal, and negative (–) lead to
negative (–) terminal.

6. Charge battery according to charger and battery

manufacturers’ instructions.

7. Reinstall battery on unit and connect positive (+)

cable first, then negative (–) cable.

It may be possible to recharge the battery by jump
starting the unit and allowing the engine to run.

Jump Start

The unit used for jump starting should have a 12-volt
battery with at least 500 cold cranking amperes, and a
negatively grounded system.

1. Ensure battery is not frozen. If the fluid is frozen,

remove battery from unit and allow it to thaw
before charging.

2. Connect the positive (+) jumper cable to the

positive terminal of the discharged battery.

3. Connect the other end of the same jumper cable

to the positive (+) terminal of the booster battery.

4. Connect one end of the second jumper cable to

the negative (–) terminal of the booster battery.

WARNING: AVOID INJURY. Read and
understand the entire Safety section before
proceeding.

WARNING: FROZEN BATTERIES CAN
EXPLODE
and result in death or serious
injury.

DO NOT charge a frozen battery. Let the
battery thaw before charging.

1

2

3

4

1. Armature
2. Rotor

3. Inspection Slot
4. Gap Adjustment

Nut

4

Figure 14

OG1500

1. Positive terminal
2. Negative terminal

3. Battery

2

1

3

OF1670

Figure 15