beautypg.com

Error codes – GE DCVH515 User Manual

Page 47

background image

– 47 –

Error Code

Component,

System, or Test

Description

Critical

Failure

E00

All

No error

No

E01

EEPROM

EEPROM failure

Yes

E02

Inlet thermistor

Inlet thermistor short circuit

No

E03

Outlet thermistor Outlet thermistor short circuit

No

E04

Inlet thermistor

Open circuit

No

E05

Outlet thermistor Open circuit

No

E60

Door switch

Door switch malfunction

No

E61

Control board

L2 and N incorrectly wired (ac input too high)

Yes

E80

Control board

Invalid UI model

No

E81

Control board

Invalid power model

No

Error Codes

NOTE: It’s important to note error codes should only be used to help identify those components which
require testing. Never replace a part based solely on an error code. The control can generate a false error
if the right conditions exist. Use the code only as a reference and always check the component before
replacing.