beautypg.com

Only – GarrettCom DS80C User Manual

Page 20

background image

Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)

15

www GarrettCom com

.

.

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125

µ

m

(m.m.) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

The following data has been collected from component manufacturer’s (HP’s and Siemens’) web
sites and catalogs to provide guidance to network designers and installers.

Fiber

Port

Module

Speed,

Std.

Mode

Std. km

fdx

(hdx)

Wave-

length

nm

Cable

Size

µµµµ

m

X’mitr

Output

P

T ,

dB

R’cvr

Sens.

P

R ,

dB

Worst

OPB,

dB

Worst*

distance
Km, fdx

typical

OPB,

dB

typical*

distance
Km, fdx

DS80F-

MST, MSC

100Mb

FX

Multi-

mode

2

(0.4)

1300 62.5/125

50/125

-20

-23.5

-31

-31

9.0

5.5

2.5

2.0

14

12

5

4

DS80F-SSC

100Mb

FX

Single-

mode

20

(0.4)

1300

9/125

-15

-31

14

28

17.5

35

DDS80F-

MTRJ

100Mb

FX

Multi-

mode

2

(0.4)

1300 62.5/125

50/125

-20

-23.5

-31

-31

9.0

5.5

3.0

2.0

15.8

12.2

5.5

4.0

Long Reach

100Mb

FX

Single-

mode

40

(0.4)

1300

9/125

-5

-34

29

58

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over

long distances (i.e., over approx. 400 meters) can be achieved

only

if the following

factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, and

The worst-case OPB of the fiber link must be greater than the fiber cable’s passive
Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

3.2.6

Connections to NICs which support Auto-Negotiation, RJ-45 ports

The copper ports of Magnum DS80F and DS80C Dual-Speed Hubs will function

properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast

Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a NIC to the

DS80F or DS80C, it may be necessary to reload the NIC drivers on the user device if the NIC

has been communicating with a protocol other than 100BASE-TX (such as 10BASE-T). When

100Mb operation is agreed and in use, the SPEED LED is illuminated steady ON. It is OFF if

no traffic or if 10Mbps traffic.

3.3

Powering the Magnum DS80F and DS80C

Each Magnum DS80F and DS80C Personal Hub is provided with an external power

supply, and has a jack for the DC power cord in the rear. A lightweight DC power cord for

This manual is related to the following products: