Installation instructions, Technical specification, Covering the following models – Stovax Logic Hotbox & Convector Fire User Manual
Page 8
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
Covering the following models
Hotbox
Convector
8306PBUC
8308PBUC
P80306PBUC
P8308PBUC
8306MCUC
8308MCUC
P8306MCUC
P8308MCUC
GAS CATEGORY
1
2h
1
3+
Natural
Butane
Propane
Gas Type
G20
G30
G31
Working Pressure
20 mb
29 mb
37 mb
Gross Input kW
High
6.7
6.7
6.7
Low
3.0
3.0
3.0
Gas Rate m
3
/hr
High
0.64
0.192
0.252
Low
0.29
0.086
0.113
Nox Class
1
1
Injector size
400
180
6x5 Rear
Aeration Size
6x15
23x15 Front
Min flue size
5” diameter
Min Flue size - Pre cast
90mm x 183 mm (16,500mm
2
min)
Min flue specifacation
T160 / N2 / 0 /D / 1
Gas Inlet
8mm
Weight (Gross)
19Kg
APPLICABLE FRONTS
FRONT
HOTBOX
CONVECTOR
DESIGNIO
8251MA
8251MA
EVOLUTION
8255MB, 8255BS
8257MB, 8257BS
HOLYROOD
8391
8397
8150
8391
8397
8150
INFINITI
8249BS
8249BS
PROGRESS
8253BS
8253BS
RICHMOND
N/A
8678
SPANISH
8382, 8385
8388, 8153
8382, 8385
8388, 8153
VICTORIAN
CONVECTOR
N/A
4262, 4263
ART NOUVEAU
CONVECTOR
N/A
4264, 4265
COMBINATION
CONVECTOR
N/A
4362, 4363
8