Model G0466/G0469 Air Compressors

-

8

-

Extension Cords

The use of extension cords can cause
power loss and overheating in air com-
pressors. When possible, locate the air
compressor where it can be plugged into
an outlet without the use of an extension
cord, and use an additional air hose to
reach the work area.

If you find it necessary to use an exten-
sion cord with your machine:

• Make sure the cord is rated Standard

Service (grade S) or better.

• The extension cord must contain a

ground wire and plug pin.

• Use at least a 14 gauge cord. Use a

12 gauge cord if the cord is between
25-100 feet.

• DO NOT use extension cords over 100

feet.

Electrocution

or

fire could result if
this machine is not
grounded correctly or
if your electrical con-
figuration does not
comply with local and
state codes. Ensure
compliance by check-
ing with a qualified
electrician!

Grounding

In the event of an electrical short, ground-
ing reduces the risk of electric shock. The
grounding wire in the power cord must
be properly connected to the grounding
prong on the plug; likewise, the outlet
must be properly installed and grounded.
All electrical connections must be made
in accordance with local codes and ordi-
nances.