Wiring Diagram #091-182

T3

T3

T3

1

1

T4

A

T2

T3

T3

T4

T4

T4

B

T2

T3

T3

1

1

T1

C

T3

T3

T3

T1

T1

T4

D

T2

T3

T3

T1

T1

T4

E

T2

T3

T3

T1

T1

T2

F

NOTE: USE WIRE NUT FOR 1 - 1 CONNECTION

5000 WATT / 240V HEATERS

* SEPARATE 120V REQUIRED FOR CONTROLS (3 AMP LOAD)

2.0 KW - 120/208V - 1 PH - 3 WIRE - 9 AMPS
2.5 KW - 120/240V - 1 PH - 3 WIRE - 11 AMPS
4.0 KW - 120/208V - 1 PH - 3 WIRE - 18 AMPS
5.0 KW - 120/240V - 1 PH - 3 WIRE - 21 AMPS
5.5 KW - 120/208V - 1 PH - 3 WIRE - 27 AMPS
7.5 KW - 120/240V - 1 PH - 3 WIRE - 31 AMPS
7.5 KW - 120/208V - 1 PH - 3 WIRE - 38 AMPS
10.0 KW - 120/240V - 1 PH - 3 WIRE - 42 AMPS
11.5 KW - 120/208V - 1 PH - 3 WIRE - 54 AMPS
15.0 KW - 120/240V - 1 PH - 3 WIRE - 63 AMPS
11.5 KW - 120/208V - 3 PH - 4 WIRE - 31 AMPS
15.0 KW - 240V - 3 PH - 3 WIRE - 36 AMPS *

A

B

C

D

E

F

WIRE PER FIG.

FOR THIS HEAT AND ELECTRIC SERVICE

* FOR 3 PHASE WIRING

1. MOVE WIRE 6 FROM L1 TO L3
2. CONNECT HEATER ACCORDING TO FIG. F
ON CHART
3. FIG. F FOR 3 PH ONLY

WIRES 5 6 7 8 ARE 8 AWG, 105°C

1 2 3 4 ARE 10 AWG, 105°C

A