SECTION 3 – INITIAL OPERATION
Function control
To check the function controls, the induction generator must 
be totally connected.
Display
1. The external lamps must be checked.
2. The operation lamp fl ashes if a coil is not used (Searching
function).
3. This procedure must be repeated for every coil.
Pan Detection
To check the pan detection, two pans are needed: one with a 
diameter of 8cm (3”) and the other with a diameter of 12cm 
(4.75”) .Only the pan with a diameter of 12cm (4.75”) should 
be detected. A coil should not start operation when it is not 
being used.
This procedure must be repeated for every coil.
Power
Place an “induction ready” pan with a diameter of 22-24cm 
(8.5”-9.5”) onto the coil. Measure the generator power 
at maximum level. This should be at the nominal power 
(tolerance +/- 10%). This procedure must be repeated for 
every coil.
Fan
Place various pans on the coils and start the generator on 
the highest level. After a few minutes the fan should start. 
The fan is controlled by the temperature and starts when the 
heat sink temperature is about 50ºC/122ºF.