beautypg.com

User instructions, Cleaning the nemos, Arrangement of fuel bed components – Stovax Riva Nemos 8627 MA User Manual

Page 5

background image

5

USER INSTRUCTIONS

5. CLEANING THE NEMOS

ENSURE THE APPLIANCE IS COLD BEFORE PROCEEDING.
5.1 The outside casing of the Nemos should be cleaned using a

damp cloth. If you have a stainless steel door version, it

should be cleaned using a stainless steel cleaner.

5.2 To clean the burner system, firstly depress the front door

centrally on the RH side and the door will release allowing

you to open fully. See diagram 1.

1

AR1287

5.3 Remove the glass panel by unscrewing the nine pozidriv

screws. See diagram 2.

2

AR0816

5.4 Remove the ceramic logs and place on a dry, clean surface.

It is not essential to remove the embers.

5.5 The logs should not require cleaning. Do not use a vacuum

cleaner or brush to clean the logs, any large pieces of debris

may be removed by hand.

5.6 Ensure any debris is removed from the burner ports.
5.7 Replace the ceramics and door by referring to section 6.

5.8 To clean the glass surface, Gazco recommends you use a

ceramic glass product generally sold for cleaning ceramic

hobs.

6. ARRANGEMENT OF FUEL BED

COMPONENTS

ADVICE ON HANDLING AND DISPOSAL OF FIRE

CERAMICS

The fuel effect and side panels in this appliance are made

from Refractory Ceramic Fibre (RCF), a material which is

commonly used for this application.

Protective clothing is not required when handling these

articles, but we recommend you follow normal hygiene

rules of not smoking, eating or drinking in the work area

and always wash your hands before eating or drinking.

To ensure that the release of RCF fibres are kept to a

minimum, during installation and servicing a HEPA filtered

vacuum is recommended to remove any dust accumulated

in and around the appliance before and after working on it.

When servicing the appliance it is recommended that the

replaced items are not broken up, but are sealed within

heavy duty polythene bags and labelled as RCF waste.

RCF waste is classed as stable, non-reactive hazardous waste

and may be disposed of at a licensed landfill site.

Excessive exposure to these materials may cause temporary
irritation to eyes, skin and respiratory tract; wash hands
thoroughly after handling the material.

6.1 Place log A on to the burner. Ensure the rear of the log

touches the rear of the burner. See diagram 3.

AR0816

3

CENTRALISE THE LOG BETWEEN THE BURNERPORTS AT

EITHER END

Four of the remaining logs have location holes on the

underside. These locate on the studs at the front of the fire.

6.2 Place log D on the third stud from the left and resting at the

rear of log A. See diagram 4.

This manual is related to the following products: