Manufactured for: General Electric Company, Louisville, KY 40225

Performance Data Sheet

SmartWater Filtration System

GWF / HWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Effluent

% Reduction

Min. Required

MCL

Challenge Concentration

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

0.02 ppm

0.05 ppm

98.90%

97.37%

> 50%

T & O

Particulate**

at least 10,000 particles/mL

3,978

7,800

98.00%

96.10%

> 85%

Standard No. 53: Health Effects

Parameter

USEPA

Influent

Effluent

% Reduction

Min. Required

MCL

Challenge Concentration

Average

Maximum

Average

Minimum

Reduction

Turbidity

1 NTU***

11 + 1 NTU***

0.07 NTU

0.1 NTU

99.71%

99.59%

0.5 NTU

Cysts

99.95% Reduction

Minimum 50,000 L

26

55

99.97%

99.95%

> 99.95%

Lead at pH 6.5

15 ppb

0.15 mg/L + 10%

1 ppb

1 ppb

99.37%

99.37%

0.010 mg/L

Lead at pH 8.5

15 ppb

0.15 mg/L + 10%

1.8 ppb

4.3 ppb

98.8%

97.13%

0.010 mg/L

Lindane

0.0002 ppm

0.002 mg/L + 10%

0.00005 ppm

0.00005 ppm

91.93%

91.93%

0.0002 mg/L

Atrazine

0.003 ppm

0.009 mg/L + 10%

0.002 ppm

0.003 ppm

76.19%

64.28%

0.003 mg/L

2,4-D

0.100 ppm

0.210 mg/L + 10%

0.042 ppm

0.090 ppm

84.89%

67.63%

0.07 mg/L

Asbestos

99%

10

7

to 10

8

fibers/L;

0.32 MFL/ml

1.2 MFL/ml

99.95%

99.82%

99%

fibers greater than

10 micrometers in length

* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C
** Measurement in Particles/ml. Particles used were 0.5–1 microns
*** NTU=Nephelometric Turbidity units

Operating Specifications

Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light; up
to one year for models with a replacement filter indicator light
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your
water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

NSF

®

System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for
the reduction of:

Standard No. 42: Aesthetic Effects
Chemical Unit

Taste and Odor Reduction
Chlorine Reduction

Mechanical Filtration Unit

Particulate Reduction, Class I

Standard No. 53: Health Effects
Chemical Reduction Unit

Lead and Atrazine Reduction
Lindane and 2,4-D Reduction

Mechanical Filtration Unit

Turbidity Reduction
Cyst and Asbestos Reduction