7.8 Carefully insert the front coal retainer into the front panel of
the firebox. Take care not the scrape/damage the logs. This
coal retainer sits in two brackets. Ensure it is fully inserted,
leaving approximately a 4 mm gap between the firebox
ledge and the bottom of the coal retainer.
7.9 Ensure that the fibreglass seal on the back of the door is
intact, locate the door on the four studs and slide back to
the firebox. Secure in place using the four dome nuts and
tool supplied. Do not overtigthen the nuts, see diagram 11.
NEVER OPERATE THE STOVE WHEN THE DOOR IS
REMOVED.
8. GAZCO FLUE SURE SYSTEM
8.1 The stove is fitted with the Gazco Flue Sure System, which
will act to cut off the gas supply to the burners in the event
of incorrect operation of the flue. If the system acts to cut off
the gas supply, this indicates that there is insufficient flue
pull. If this occurs a minimum of 10 minutes should be
allowed before trying to relight. Continued operation of this
safety device means there may be a serious problem with
the flue system. A qualified gas engineer should inspect this.
DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS IT
IS SAFE TO DO SO.
9. THE FLAME FAILURE DEVICE
9.1 This is a safety feature incorporated in all GAZCO fires
which automatically switches off the gas supply if the pilot
light goes out and fails to heat the thermocouple.
10. ‘RUNNING IN’
10.1 The surface coating on your GAZCO fires will "burn off"
during the first 24 hours of use, producing a harmless and
temporary odour. This will disappear after the short period
of use. If the odour persists, ask your retailer for advice.
11. SERVICING
11.1 A qualified gas engineer must service the stove every 12
months. In all correspondence, always quote the appliance
type and the Serial Number that may be found on the
databadge on the appliance.
12. VENTILATION
12.1 Any purpose provided ventilation should be checked
periodically to ensure that it is free from obstruction.
13. INSTALLATION DETAILS
13.1 To assist in any future correspondence, your installer should
have completed the commissioning sheet at the front of this
manual. This records the essential installation details of this
appliance. In all correspondence always quote the Model
No. and Serial No.
14. HOT SURFACES
14.1 The manufacturer consider the full outer casing of this stove
to be a working surface. Therefore it will become hot whilst
in operation. A suitable guard is recommended to protect
young children, the aged and the infirm.