beautypg.com

User instructions, Gazco flue sure system, The flame failure device – Stovax 705088 User Manual

Page 7: ‘running in, Servicing, Ventilation, Installation details, Hot surfaces

background image

7.8 Carefully insert the front coal retainer into the front panel of

the firebox. Take care not the scrape/damage the logs. This

coal retainer sits in two brackets. Ensure it is fully inserted,

leaving approximately a 4 mm gap between the firebox

ledge and the bottom of the coal retainer.

7.9 Ensure that the fibreglass seal on the back of the door is

intact, locate the door on the four studs and slide back to

the firebox. Secure in place using the four dome nuts and

tool supplied. Do not overtigthen the nuts, see diagram 11.

NEVER OPERATE THE STOVE WHEN THE DOOR IS

REMOVED.

8. GAZCO FLUE SURE SYSTEM

8.1 The stove is fitted with the Gazco Flue Sure System, which

will act to cut off the gas supply to the burners in the event

of incorrect operation of the flue. If the system acts to cut off

the gas supply, this indicates that there is insufficient flue

pull. If this occurs a minimum of 10 minutes should be

allowed before trying to relight. Continued operation of this

safety device means there may be a serious problem with

the flue system. A qualified gas engineer should inspect this.
DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS IT

IS SAFE TO DO SO.

9. THE FLAME FAILURE DEVICE

9.1 This is a safety feature incorporated in all GAZCO fires

which automatically switches off the gas supply if the pilot

light goes out and fails to heat the thermocouple.

10. ‘RUNNING IN’

10.1 The surface coating on your GAZCO fires will "burn off"

during the first 24 hours of use, producing a harmless and

temporary odour. This will disappear after the short period

of use. If the odour persists, ask your retailer for advice.

11. SERVICING

11.1 A qualified gas engineer must service the stove every 12

months. In all correspondence, always quote the appliance

type and the Serial Number that may be found on the

databadge on the appliance.

12. VENTILATION

12.1 Any purpose provided ventilation should be checked

periodically to ensure that it is free from obstruction.

13. INSTALLATION DETAILS

13.1 To assist in any future correspondence, your installer should

have completed the commissioning sheet at the front of this

manual. This records the essential installation details of this

appliance. In all correspondence always quote the Model

No. and Serial No.

14. HOT SURFACES

14.1 The manufacturer consider the full outer casing of this stove

to be a working surface. Therefore it will become hot whilst

in operation. A suitable guard is recommended to protect

young children, the aged and the infirm.

7

USER INSTRUCTIONS

10

AR1617

11

AR0540