beautypg.com

Servicing instructions, Replacing parts, Primary aeration plate – Stovax 705088 User Manual

Page 20

background image

20

SERVICING INSTRUCTIONS

REPLACING PARTS

9.3 Undo the two screws at the back of the firebox and carefully

withdraw the bracket.

9.4 Disconnect the two slender wires. Undo the two taptite

screws and remove the sensor and the two plastic spacers.

See diagram 16.

9.5 Refit the new sensor, ensuring that the plastic spacers are

between the sensor and the bracket. Refit the leads. See

Diagram 17.

9.6 Feed the cable back through the hole as you replace the

bracket. When the bracket is located correctly it will sit

flush with the back panel without force required. If not

positioned correctly the bracket will sit at an angle. See

Diagram 18.

10. PRIMARY AERATION PLATE

10.1 Turn the gas supply off at the isolation device.
10.2 Refer to Section 2 to remove the main burner.
10.3 Remove the two screws on the burner skin to detach the

venturi cover from the venturi. Slide the venturi cover off the

venturi as per diagram 19.

10.4 Change the aeration plates to those stated in the technical

specification for the gas the product will be using, refer to

the databadge.

AR1607

15

AR1446

16

AR1608

19

AR1452

17

AR1448

18

AR1447

AR0619

20