beautypg.com

Grandstream Networks Grandstream BudgeTone 200 User Manual

Page 35

background image

35

Automatic
Upgrade

Choose Yes to enable automatic upgrade and provisioning.
In “Check for new firmware every” field, enter the number of days to enable
BudgeTone 200 to check the server for firmware upgrade or configuration in
the defined period of days.
When set to No, BudgeTone 200 will only do upgrade once at boot up.
“Always check for New Firmware”
“Check New Firmware only when F/W pre/suffix changes”

Authenticate
Conf File

if set to Yes, cfg file would be authenticated before acceptance. This
mechanism is useful for the protection of configuration on the device from
unauthorized change.

DTMF
Payload Type

This parameter sets the payload type for DTMF using RFC2833.

Syslog Server The IP address or URL of System log server. This feature is especially useful

for ITSP (Internet Telephone Service Provider)

Syslog Level

Select the ATA to report the log level. Default is NONE. The level is one of
DEBUG, INFO, WARNING or ERROR. Syslog messages are sent based on
the following events:

product model/version on boot up (INFO level)

NAT related info (INFO level)

sent or received SIP message (DEBUG level)

SIP message summary (INFO level)

inbound and outbound calls (INFO level)

registration status change (INFO level)

negotiated codec (INFO level)

Ethernet link up (INFO level)

SLIC chip exception (WARNING and ERROR levels)

memory exception (ERROR level)

The Syslog uses USER facility. In addition to standard Syslog payload, it
contains the following components:

GS_LOG: [device MAC address][error code] error message

Here is an example: May 19 02:40:38 192.168.1.14 GS_LOG:
[00:0b:82:00:a1:be][000] Ethernet link is up

NTP server

URI or IP address of the NTP (Network Time Protocol) server, which will be
used by the phone to synchronize the date and time.