beautypg.com

Global Machinery Company AC30G User Manual

Page 12

background image

4. To stop the compressor, push the On/Off switch down.

Operation

1. The pressure in the tank is controlled by the action

of the pressure switch located under the pressure

switch cover (2). When the set maximum pressure is

reached the pressure switch activates and the motor

is switched off. The pressure then decreases as the air

is used by the connected tool until the set minimum

pressure is reached after which the pressure switch

causes the motor to switch on again. The operator of

the compressor should be well aware that during use of

the compressor the motor will start and stop under the

influence of the rising or falling pressure in the tank.

The motor will start without any warning.

2. The maximum and minimum pressures are factory set

and the operator should not try to change them.

3. All accessories are

connected to the regulated

outlet valve (6).

4. The pressure of the

regulated outlet, as shown

on the regulated outlet

pressure gauge (7), can

be changed by turning the

regulating knob (5).

NOTE.

To obtain the correct output reading on the

regulated output gauge, the air must be flowing through

the outlet.
The regulating valve should be adjusted and the gauge

read with the outlet valve open and the air being

discharged from the regulated outlet through the

accessory being used.
To increase the air pressure, rotate the regulating valve

clockwise. To decrease the pressure, rotate the regulating

valve anti-clockwise.

NOTE.

If you do not allow the air to discharge while you

are setting the regulator, the pressure as indicated on the

regulated outlet gauge will be incorrect. This gauge ONLY

indicates the correct pressure while air is being discharged

from the outlet.
5. On completion of the task, i.e. when you have finished

using the compressor, or when you are leaving the

compressor unattended, turn off the compressor in the

following way:

Press down the on/off switch (3).

Wait for the pressurised air to bleed from the release

valve under the pressure switch cover (2).

NOTE.

When you press the button down you should hear

a short air discharge (Approx 1/2 second).

Switch off the electrical

power supply and remove

the electrical plug.

Pull the ring on the safety

valve (8) to ensure all the

pressurised air is released

from the tank, or open the

drain cock to release the

pressure from the tank.

WARNINGS.

1. Never attempt to remove any part of the compressor

whilst the tank is under pressure.

2. Never attempt to remove any electrical component

whilst the compressor is connected to the power

supply. Switch off the power and remove the electrical

plug.

3. Do not adjust the safety valve.
4. Do not use an electrical extension cable.
5. If the release valve under the pressure switch cover

(2) fails to operate when the on/off button is pressed

down, switch the power supply off and determine the

nature of the fault.

6. Ensure that the lubricating oil is clean and that the oil

level is maintained at the mid point of the red circle in

the oil level glass (17).

12

AC30G_AC40G

12/8/05, 4:49 PM

12

This manual is related to the following products: