beautypg.com

Notice, Disabling & locking switch, Installation – Grizzly H8242 User Manual

Page 2

background image

-2-

h8242 220V/240V on/oFF paddle switch

Disabling & Locking Switch

Figure 3. switch disabled by a padlock.

The switch can be disabled and locked by insert-
ing a padlock through the ON/START button, as
shown. Locking the switch in this manner can
prevent unauthorized operation of the machine,
which is especially important if the machine is not
stored inside an access-restricted building.

IMPORTANT: Locking the switch with a padlock
only restricts its function. It is not a substitute
for disconnecting power from the machine when
adjusting or servicing.

Shaft

Padlock

ON

/

START

Button

OFF

/

STOP

Paddle

Figure 4. Minimum lock shaft requirements.

NOTICE

The padlock shaft diameter is important to

the disabling function of the switch. With

any padlock used to lock the switch, test

the switch after installation to ensure that it

is properly disabled.

Children or untrained people can be killed

or seriously injured by this machine. This

risk increases with unsupervised operation.

To help prevent unsupervised operation,

disable and lock the switch before leaving

machine unattended! Place key in a well-

hidden or secure location.

Installation

When installing the h8242 switch, use the wiring
diagram in

Figure 2 to ensure proper wire con-

nections.

Rear View

of Switch

Hot
Out

Hot

In

Machine

Power Source

Verified

Ground*

Hot

In

Hot
Out

14

13

24

23

KJD17B

IP55

KEDU

Figure 2. h8242 wiring diagram.

This switch is intended to be connected to

stranded wire with insulated quick-discon-

nect crimp-type female wire terminals hav-

ing a

1

4

" tab.

All crimps must be "pull-checked" to ensure

that wires are securely crimped and will

not fall out with moderate tension or when

exposed to normal machine vibration.

*the machine MUst be connected to a verified
ground. in the event of certain malfunctions or
breakdowns, grounding reduces the risk of elec-
tric shock by providing a path of least resistance
for electric current.