Manual operation of functions – Genie TZ-50 User Manual
Page 25
Part No. 82900
Genie TZ-50
23
Operator's Manual
First Edition • Sixth Printing
OPERATING INSTRUCTIONS
Australian models only:
1 Open the valve of the desired function.
Turntable rotate right: Push in and turn
clockwise.
Turntable rotate left: Pull out and turn
counterclockwise.
Platform extend: Push in and turn clockwise.
Platform retract: Pull out and turn
counterclockwise.
Secondary boom down, primary boom up/down:
Push in and turn counterclockwise.
2 Operate the hand pump.
3 Reset the valve. The machine will not function
unless the valves are reset.
Turntable rotate right: Turn counterclockwise.
Turntable rotate left: Turn clockwise.
Platform extend: Turn counterclockwise.
Platform retract: Turn clockwise.
Secondary boom down and primary boom up/
down: Push in and turn clockwise.
Manual Operation of Jib (Australian models
only)
The jib boom lowering manifold is located on the
primary extension boom.
1 Turn the jib manifold knob counterclockwise to
lower the jib.
2 To reset, turn the knob clockwise as far as it will
go.
Manual Operation of Functions
Manifold valves are located under the cover on the
ground controls side of the machine.
Machine functions can be operated with the hand
pump located on the manifold.
All models except Australia:
1 Open the valve of the desired function.
Turntable rotate right: Push in and hold.
Turntable rotate left: Pull out and hold.
Platform extend: Push in and hold.
Platform retract: Pull out and hold.
Secondary boom down and primary boom
up/down: Push in and turn counterclockwise
until the button pops into place.
2 Operate the hand pump.
3 Reset the valve. The machine will not function
unless the valves are reset.
Turntable rotate and platform extend/retract: Let
go.
Secondary boom down and primary boom up/
down: Push in and turn clockwise until the
button pops into place.
Primary Boom
Extend/Retract
Turntable Rotate
Secondary Boom Down
Primary Boom Down
Primary Boom Up
Jib manifold knob