Ac adapter, Power management functions, Adapter loading control – GIGABYTE G-MAX N501 User Manual
Page 82

72
G-MAX
TM
N501 User’s Manual
AC Adapter
•
Universal AC adapter module. Lite-on 60W 90-264V AC, 47-63Hz, or
•
Universal AC adapter module. API 60W 90-264V AC, 47-63Hz
Power Management Functions
•
Standby mode, Suspend to RAM, or Suspend to Disk mode, by time out or
by hot key
•
HDD Local Stand-By mode by time out
•
LCD Local Stand-By mode by time out
•
Low battery alarm by beep
•
Auto-backlight off when LCD cover closed
•
Full ACPI 1.0B supported
•
LCD Auto-DIM mode by time out
Adapter loading control
If system power drain is more than adapter loading, EC will determine this
power adapter is a wrong one and notifies as below
• Flash system state LED and DC-DC state LED 500 ms every 1 second.
• Beep alarm every 2 seconds.
• With battery, system will stop charge if battery is not full.
• Without battery, system will shutdown if system power on.
Note When EC determine the adapter is a wrong one, LED will keep flashing
and system alarm will keep beeping until adapter plug-out or system off.