Servicing instructions, Replacing parts, Magnetic safety valve – Stovax Marlborough & Stockton Coal Effect Stove Range User Manual
Page 20: Main injector, Gazco flue sure system, Primary aeration plate
20
6.5 Disconnect the ignition lead from the gas valve.
6.6 Undo the two bolts securing the gas valve to the appliance
and remove the valve.
6.7 Replace in reverse order.
6.8 Check all joints for gas leaks. Check operation of the
thermocouple and ignition lead.
7. MAGNETIC SAFETY VALVE
7.1 Turn the gas supply off at the isolation device. Undo the
thermocouple connection from the back of the gas valve.
Pull the sensor leads clear and remove the interrupter block.
7.2 Undo the magnetic valve-retaining nut from the back of the
control valve. Gently tap out the magnetic valve and replace
with a new unit. Replace the retaining nut and tighten. See
Diagram 15.
AR0943
15
7.3 Reassemble the interrupter block and leads. Secure the
thermocouple connection in the rear of the gas control. (Do
not overtighten). Turn the gas supply on and check the
entire pipework and valve joints for any leaks.
8. MAIN INJECTOR
8.1 Turn the gas supply off at the isolation device. Locate the
main injector on the LH side of the airbox, undo the
compression nut and pull the pipe clear of the injector
body, see Diagram 16, A.
AR0389
A
16
8.2 Rotate the injector until it is fully removed, and install the
correct replacement injector. Reassemble and turn the gas
supply on, check for leaks.
9. GAzCO FLUE SURE SYSTEM
If the stove has been installed in a restrictive location, it
may be necessary to remove the stove from its location.
9.1 Locate the sensor in the draught diverter opening, and
gently pull the two wires off the terminals. Undo the two
taptite screws and remove the sensor and the two plastic
spacers. See Diagram 17.
17
AR0380
9.2 Refit a new sensor ensuring the spacers are located between
the sensor and the bracket. Replace the two leads.
9.3 If it has been necessary to remove the stove, ensure that all
disturbed gas joints are checked for gas soundness when
reinstalled, and repeat the flue clearance test as detailed in
the Commissioning Section.
10. PRIMARY AERATION PLATE
10.1 Turn the gas supply off at the isolation device.
10.2 Locate the aeration plate on the underside of the airbox
and remove the Nyloc nut, see Diagram 18.
AR0381
18
10.3 Remove the plate and replace with the correct size, ensure
that the hole(s) in the plate align correctly with the holes in
the underside of the airbox and replace the Nyloc nut.
SERVICING INSTRUCTIONS
REPLACING PARTS