17
HVI CFM/Static Pressure in inches of WG
Model
RPM AMPS Watts
Sones
0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 1.000
CFM
67
53
51
40
29
SP-B50
625
0.50
38
1.4
Sones
1.7
1.9
1.9
2.6
3.5
CFM
77
70
68
57
49
39
SP-B70
675
0.53
45
1.4
Sones
1.7
1.9
1.9
2.4
3.1
3.6
CFM
87 80 78 68 61 54 44 30
SP-B80
900
0.60
54
2.5
Sones
2.9 2.9 3.0 3.2 3.6 4.3 5.5 5.6
CFM
102 92 88 75 59 45 30
SP-B90
700
0.65
50
2.0
Sones
1.9 2.6 2.7 3.0 3.6 4.1 4.9
CFM
133
114
110
97
95
94
91
85
50
SP-B110 950
1.14
80
1.5
Sones
2.0 2.1 2.2 2.4 2.7 2.8 3.6 4.4 5.4
CFM 160 156 155 154 152 149 147 138 92
SP-B150 1050 1.70
129
2.5
Sones
3.0 3.3 3.3 3.7 4.3 4.5 5.0 5.3 5.8
CFM 197 195 194 191 187 184 181 166 128
SP-B200 1100 2.20
173
4.0
Sones
4.4 4.6 4.7 5.1 5.6 5.8 6.0 6.3 6.6
Performance Data
Dimensional Data
*Add 1½
inches to C dimension for incandescent light.
Mounting bracket width is 1½
inch
For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.
Model A B C
D E F Grille Wt.
50 7
1
/
2
7
1
/
2
3
5
/
8
3 1
5
/
8
1
/
2
9
1
/
4
x 9
5
Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.
Performance Data
CFM/Static Pressure in inches of WG
Model
RPM AMPS Watts
0.00
0.100
0.125
0.250
0.375
0.500
0.625
CFM
52 49 48 46 43 37 29
SP-C50
1680
0.80
46
Sones
2.9 3.6 3.6 3.9 4.2 4.8 6.3
Dimensional Data
For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.
Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.
5 UL Listed for use above tubs.
6 Available with 277 volt motor.
1 HVI sones at 0.1 wg
2 Available with light
3 Available with CRD - Ceiling Radiation Damper
4 Available with 50 Hz motors
(See CAPS for performance)
Designer Decorative
Unit
Model
A B *C
D
E
Grille
Grille
Wt.
50, 70, & 80
13
7
/
8
11
1
/
2
6
15
/
16
4
3
/
4
14
7
/
8
x 13
1
/
4
15
1
/
4
sq.
9
90, 110, 150, 200
13
7
/
8
11
1
/
2
7
15
/
16
6
1
1
/
4
14
7
/
8
x 13
1
/
4
15
1
/
4
sq.
10
1
2,3,5
2,3,5
2,3,4,5,6
3,4,5,6
2,3,4,5,6
2,3,4,5
2,3,5
A
B
C
D
E
A
B
C
D
E
F
®
®