beautypg.com

Troubleshooting (cont.), Brewing problems – Grindmaster SHUTTLE APB-330V2 User Manual

Page 26

background image

Page 26

Shuttle Brewers & Airpot/Shuttle Brewers

Troubleshooting (cont.)

Brewing Problems

Problem

Possible Causes

Service Check

Remedy

Brew cycle will
not start

• Controller faulty.

• Check to see that the

power is supplied to the
controller by following
instructions given in
the Troubleshooting
section
on Filling
Problems.
Once
touchpad and momentary
switch integrity is
assured (see above),
initiate a brew cycle
and check for 24 Vac
across brew valve.

• If there is not 24 Vac across

brew valve, replace control
board.

Sprayhead will not
stop dripping water

• Brew valve not closing

completely.

• Water in tank boiling.

• Visually inspect brew

valve at hose
connections.

• Remove sprayhead

and determine if drip is
coming from overflow.

• Clean lime from valve. Seat,

cup or entire valve may need
replacement.

• Reduce tank temperature.

If you still need help, call our Service Department at (800) 695-4500 (USA and Canada only) or (502) 425-4776
(Monday-Friday 8:00 am - 6:00 pm EST) or an authorized service center in your area. Please have the model
and serial number ready so that accurate information can be given.

Prior authorization must be obtained from Grindmaster-Cecilware’s Technical Services Department for all
warranty claims.

A530-066 Control Board

used on all PrecisionBrew™ V2.0 models

Refers to software version number.
Subject to change.