beautypg.com

Grindmaster SHUTTLE APB-330V2 User Manual

Page 19

background image

Shuttle Brewers & Airpot/Shuttle Brewers

Page 19

Factory/Field Test Menu (cont.)

Step

Function

Operation

Description

1

LED Test

All LEDs ON

Verify that all LEDs turn on.

2

Firmware Version

Display firmware version

Shows the software version of the control.

3

Date Code

Not used

Not used

4

EEPROM Version

Not used

Not used

5

Non Resetable Unit
Counter

Scroll non-resetable unit counter

Shows the total number of brews made by
the brewer (both sides if a double unit)

6

Display Water
Temperature

Show averaged A/D reading of temperature Shows the current temperature in °F of the

thermister.

7

Display Water Level 1

Show averaged A/D reading of water level 1 If > 500 water level is full,

If < 500 water level is not full.

8

Display Water Level 2

Show averaged A/D reading of water level 2 If > 500 water is at the heater level,

If < 500 water level not at the heater level.

9

Show Input

Display scrolls “InPut

Input Test Mode

10

Input Test

Press each key and the display will show a
number related to that key

Right Side
On/Off - 1 (advances test)
Up - 5
Down - 3
Large Brew - 4
Medium Brew - 2
Small Brew - 0
Basket Switch - 17
Left Side
On/Off - 9
Up - 13
Down - 11
Large Brew - 12
Medium Brew - 10
Small Brew - 8
Basket Switch - 16

11

Show Output

Display scrolls “outPut

Output Test Mode

12

Output Test

Turns on each relay separately. Displays
“O##“ where:

## = 2 digit output number

IMPORTANT: Each output will be turned
ON when its number is on the display
REGARDLESS of temperature or fill
level. Be CAREFUL not to overfill the
tank and keep electric items out of the
way of the brew channel.

Scroll through relay outputs with the UP
and DOWN keys.

Outputs are as follows:

O01 - Fill Valve
O02 - Right Bypass Valve
O03 - Left Bypass Valve
O04 - Right Brew Valve
O05 - Left Brew Valve
O06 - not used
O07 - Tank Heater
O08 - Right Basket Lock
O09 - Left Basket Lock
O10 - not used