Installation of the range.

48

Operating Instr

uctions

Installation Instr

uctions

Safety Infor

mation

Tr

oubleshooting T

ips

Customer Ser

vice

Read these instructions completely and carefully.

3-Wire Conduit Installation

Remove the 3 screws from the connector block. Insert bare wires between the
connector block terminals and movable nuts. Tighten screws securely. Do not
remove ground strap connection.

WARNING: Connector block is approved for copper wire connection
only. If aluminum wire is used, see note below.

NOTE: ALUMINUM WIRING

Do not connect aluminum wire to the connector block.

Use copper building wire rated for the correct amperage and voltage to
make 3 (three) 3² copper jumper wires. Connect wire as per Step 6 or 7
depending on number of wires.

Splice copper wires to aluminum wiring using special connector terminals
designed and UL-approved for joining copper to aluminum and follow the
connector manufacturer’s recommended procedure closely.

Wire used, location and enclosure of splices, etc., must conform to good wiring practices
and local codes.

b

a

6

Screw

Flexible cable

Bare wire tips

Conduit

Bare wire

Movable nut

Connector block

Bracket

Connector block terminal