User instructions – Stovax Ceramica Coal Effect Stove Range Conventional Flue User Manual
Page 7
13.1 Parts of this appliance become hot during normal use. It is
recommended that a suitable fire guard be used for
protection of young children and the infirm. Indeed, all
parts of the appliance should be treated as a ‘working
surface’ except for the control area.
7.1
The stove is fitted with the Gazco Flue Sure System, which
will act to cut off the gas supply to the burner in the event
of incorrect operation of the flue. If the system acts to cut
off the gas supply, this indicates that there is insufficient flue
pull. If this occurs a minimum of 10 minutes should be
allowed before trying to relight. Continued operation of this
safety device means there may be a serious problem with
the flue system. A qualified gas engineer should inspect this.
Do not use the stove until an engineer says it is safe to
do so.
8.1
This is a safety feature incorporated in all GAZCO fires,
which automatically switches off the gas supply if the pilot
light goes out and fails to heat the thermocouple.
9.1
The surface coating on your GAZCO stove will ‘burn off’
during the first 24 hours of operation on high, producing a
harmless and temporary odour. If the odour persists ask
your retailer for advice.
10.1 A qualified gas engineer must service the stove every 12
months. In all correspondence, always quote the appliance
type and the Serial Number found on the data badge on
the appliance.
11.1 Any purpose provided ventilation should be checked
periodically to ensure it is free from obstruction.
12.1 To assist in any future correspondence, your installer should
have completed the Appliance Commissioning Checklist in
this manual. This records the essential installation details of
this appliance. In all correspondence always quote the
Model No. and Serial No.
7
USER INSTRUCTIONS
8. THE FLAME FAILURE DEVICE
9. 'RUNNING IN'
10. SERVICING
11. VENTILATION
12. INSTALLATION DETAILS
13. HOT SURFACES
7. GAZCO FLUE SURE SYSTEM