beautypg.com

User instructions – Stovax Ceramica Coal Effect Stove Range Conventional Flue User Manual

Page 7

background image

13.1 Parts of this appliance become hot during normal use. It is

recommended that a suitable fire guard be used for

protection of young children and the infirm. Indeed, all

parts of the appliance should be treated as a ‘working

surface’ except for the control area.

7.1

The stove is fitted with the Gazco Flue Sure System, which

will act to cut off the gas supply to the burner in the event

of incorrect operation of the flue. If the system acts to cut

off the gas supply, this indicates that there is insufficient flue

pull. If this occurs a minimum of 10 minutes should be

allowed before trying to relight. Continued operation of this

safety device means there may be a serious problem with

the flue system. A qualified gas engineer should inspect this.

Do not use the stove until an engineer says it is safe to

do so.

8.1

This is a safety feature incorporated in all GAZCO fires,

which automatically switches off the gas supply if the pilot

light goes out and fails to heat the thermocouple.

9.1

The surface coating on your GAZCO stove will ‘burn off’

during the first 24 hours of operation on high, producing a

harmless and temporary odour. If the odour persists ask

your retailer for advice.

10.1 A qualified gas engineer must service the stove every 12

months. In all correspondence, always quote the appliance

type and the Serial Number found on the data badge on

the appliance.

11.1 Any purpose provided ventilation should be checked

periodically to ensure it is free from obstruction.

12.1 To assist in any future correspondence, your installer should

have completed the Appliance Commissioning Checklist in

this manual. This records the essential installation details of

this appliance. In all correspondence always quote the

Model No. and Serial No.

7

USER INSTRUCTIONS

8. THE FLAME FAILURE DEVICE

9. 'RUNNING IN'

10. SERVICING

11. VENTILATION

12. INSTALLATION DETAILS

13. HOT SURFACES

7. GAZCO FLUE SURE SYSTEM