Zidi240wii, Ge monogram – GE Monogram ZIDI240WII User Manual
Page 2
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
120032
Specification Created 12/07
Listed by
Underwriters
Laboratories
ZIDI240WII
GE Monogram
®
Double-Drawer Refrigerator Module
(Custom panel required)
ZIDS240WSS
GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)
Dimensions and Installation Information (in inches)
Specification Revised 7/05
120032
Grounding the Double-Drawer Refrigerator
IMPORTANT - (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong
(grounding) wall receptacle to minimize the possibility of
electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
When a standard 2-prong wall outlet is encountered, it is
your personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall
outlet.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO
CONNECT THE REFRIGERATOR TO A 2-
PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
3/4” Overlay Panel Dimensions
Model ZIDI240WII requires customer-
provided overlay door panel.
• The overlay panel must be secured to a
1/4" thick backer panel which slides into
the trim. A .10" thick spacer panel must
be placed between the custom and
backer panel.
• A custom handle of your choice,
supplied by your cabinet maker, must be
installed on the overlay panel.
Overlay
Panel
1/4"
Backer
Panel
Door
.10 Inch
Spacer
3/4" Overlay Panel Dimensions (in inches)
A (Width) B (Height)
1/4" Backer
23-3/16"
14-11/16"
0.10" Spacer
22-1/2"
14-3/16"
3/4" Overlay
23-5/8"
15-1/16"
NOTE: Max. assembled drawer panel
weight is 25 lbs.
IMPORTANT: Maintain a 1/4" gap
between the panels when installed.
Assemble overlay panels with glue
and screws.
• Center spacer panel on the backer
panel, left to right and top to
bottom. Secure the panels with glue.
• Center the spacer/backer panel on
the overlay panel. Secure with glue
and screws. Countersink screws into
the backer panel.
Spacer Panel
Backer Panel
Overlay Panel
B
A
1/4" Gap
12-1/2 lbs. max.
B