For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

120032

Specification Created 12/07

Listed by

Underwriters

Laboratories

ZIDI240WII

GE Monogram

®

Double-Drawer Refrigerator Module

(Custom panel required)
ZIDS240WSS
GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)

Dimensions and Installation Information (in inches)

Specification Revised 7/05

120032

Grounding the Double-Drawer Refrigerator

IMPORTANT - (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY

GROUNDED.
The power cord of this appliance is equipped with a 3-prong

(grounding) plug which mates with a standard 3-prong

(grounding) wall receptacle to minimize the possibility of

electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified

electrician to make sure the outlet is properly grounded.
When a standard 2-prong wall outlet is encountered, it is

your personal responsibility and obligation to have it replaced

with a properly grounded 3-prong wall

outlet.
DO NOT, UNDER ANY CIRCUMSTANCES,

CUT OR REMOVE THE THIRD (GROUND)

PRONG FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO

CONNECT THE REFRIGERATOR TO A 2-

PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.

3/4” Overlay Panel Dimensions

Model ZIDI240WII requires customer-

provided overlay door panel.
• The overlay panel must be secured to a

1/4" thick backer panel which slides into

the trim. A .10" thick spacer panel must

be placed between the custom and

backer panel.

• A custom handle of your choice,

supplied by your cabinet maker, must be

installed on the overlay panel.

Overlay

Panel

1/4"

Backer

Panel

Door

.10 Inch

Spacer

3/4" Overlay Panel Dimensions (in inches)

A (Width) B (Height)

1/4" Backer

23-3/16"

14-11/16"

0.10" Spacer

22-1/2"

14-3/16"

3/4" Overlay

23-5/8"

15-1/16"

NOTE: Max. assembled drawer panel

weight is 25 lbs.
IMPORTANT: Maintain a 1/4" gap

between the panels when installed.

Assemble overlay panels with glue

and screws.
• Center spacer panel on the backer

panel, left to right and top to

bottom. Secure the panels with glue.

• Center the spacer/backer panel on

the overlay panel. Secure with glue

and screws. Countersink screws into

the backer panel.

Spacer Panel

Backer Panel

Overlay Panel

B

A

1/4" Gap

12-1/2 lbs. max.

B

12-1/2 lbs. max.