Pre-installation checks – Stovax Riva Open Log Burning Convector Fireboxes User Manual
Page 18
2.2 Extractor fans or cooker hoods should not be placed in the
same room or space as the appliance.
2.3 If any of these checks reveal problems do not proceed
with the fitting of the appliance until they have been
rectified.
2.1 Open appliances require additional ventilation to comply
with the requirements of the Building Regulations. This
should be provided using a permanently open air vent, of
the size listed, which is positioned so that it is not liable to
be blocked both inside and outside the building.
Model
Additional Ventilation
mm2
14400
16538
19215
21735
21735
cm2
144
165
192
217
217
in2
22.32
25.63
29.78
33.69
33.69
16"
Riva
Open
22"
Riva
Open
24"
Riva
Open
26"
Riva
Open
28"
Riva
Open
2. ADDITIONAL VENTILATION
PRE-INSTALLATION CHECKS
18