RIVA OPEN
TECHNICAL SPECIFICATION
1. STANDARD FEATURES
• Damper Control
• Primary air (under grate air for full multi-fuel use)*
* Multi-fuel kits 8705, 8710, 8720 only
2. PACKING LIST
• Instructions
• Guarantee card
• Pair of gloves
• Damper/Multi-fuel grate Tool
• Poker
Model
Nominal Heat Output
Wood
kW
4
6.5
8
9
10
Solid Fuel
kW
3
4
5
5
5
Flue Draught at Nominal Heat
All Fuels
mm
1.25
1.25
1.25
1.25
1.25
inch Wg
0.05
0.05
0.05
0.05
0.05
Flue Gas Mass Flow
Wood
g/s
39.1
45.0
52.8
53.0
54.1
Solid Fuel
g/s
27.8
30.0
75.1
45.0
49.5
Flue Gas Temperature at Spigot/Socket
Wood
°C
200
155
165
180
220
Solid Fuel
°C
110
125
120
150
150
Flue Outlet Size
mm
2x(120x102) 3x(105x105) 3x(122x105) 3x(138x105) 3x(138x105)
inch
2x(4
3/4
x4)
3x(4
1/8
x4
1/8
) 3x(4
13/16
x4
1/8
) 3x(5
7/16
x4
1/8
) 3x(5
7/16
x4
1/8
)
Weight
Std
kg
62
83
86
89
97
Low
kg
59
76
81
86
-
Recommended Fuel
Wood
Seasoned wood (less than 20% moisture content)
Solid Fuel
Briquette smokeless fuel suitable for open appliances
(Homefire - Supertherm)
As tested to the requirements of EN 13229:2001 for intermittent operation
16"
Riva
Open
22"
Riva
Open
24"
Riva
Open
26"
Riva
Open
28"
Riva
Open
11