beautypg.com

Troubleshooting – Grizzly G0573 User Manual

Page 17

background image

G0573 Two Speed Floor Air Filter

-15-

Troubleshooting

Disconnect power to the

machine when perform-

ing any troubleshooting.

Failure to do this may

result in serious person-

al injury.

Symptom

Possible Cause

Possible Solution

The air cleaner does not operate at all.

1. The power supply circuit breaker is

tripped.

2. No power to the control panel
3. Wiring is at fault
4. The control panel circuit board is at

fault.

5. The motor is at fault.

1. Correct the cause for high current draw

and close the circuit breaker.

2. Replace the blown fuse in the control

panel.

3. Repair, replace wires, plugs and cables

as applicable; and make sure all electri-
cal plugs and connections are secure.

4. Replace the circuit board.
5. Replace the motor.

The air cleaner CFM output is reduced.

1. The filters are wet or clogged.
2. The airflow path is obstructed.
3. The control panel circuit board is at

fault.

4. The motor is at fault.

1. Replace the primary filter and clean the

pre-filter.

2. Remove obstructions or add ducting.
3. Replace the control panel circuit

board.

4. Replace the motor.

The air filter unit is noisy or vibrates.

1.The mounting is loose.
2. The unit is not level.
3. The fan or motor is loose.

1 Level the air cleaner unit.
2. Unplug the unit, remove the filters, and

tighten all loose fastners.