Generac Power Systems Quietpact 75 User Manual
Page 13

S
Se
ec
cttiio
on
n 2
2
M
MA
AJ
JO
OR
R G
GE
EN
NE
ER
RA
AT
TO
OR
R C
CO
OM
MP
PO
ON
NE
EN
NT
TS
S
elbow. The breather chamber contains a removable
oil vapor collector. Oil vapor is condensed on the col-
lector material and drains back into the crankcase,
which minimizes the amount of oil vapor entering the
breather.
CHECK BREATHER:
1. Disconnect breather tube and remove four screws and
breather. Discard gasket.
2. Check to see that reed valve is not deformed (Figure 2-8).
Note: Reed valve must form a complete seal
around vent hole.
3. Remove oil vapor collector and retainer.
4. Check collector for deterioration and replace if necessary.
INSTALL BREATHER:
1. Install oil vapor collector and retainer.
Note: Push oil vapor collector and retainer in until
it bottoms.
2. Install breather with new gasket (Figure 2-8).
a. Torque screws to 5-8 ft-lbs.
3. Assemble breather tube to intake elbow.
Page 11
CONTROL PANEL COMPONENT IDENTIFICATION
Figure 2-9. – Control Panel Components