Gb 5. storage, Maintenance – Gardena Pressure Tank Unit D-89070 Ulm User Manual
Page 6

15
GB
5. Storage
Storage:
If there is a risk of frost, the Pressure Tank Unit must be stored
where it will not become frozen.
1. Unplug the mains connection for the
pump.
2. Turn the rotary switch
ቩ to FILL.
3. Unscrew the drain screw
ቤ.
The Pressure Tank Unit will drain down.
4. Store the pressure tank unit in a dry,
frost-free place.
Store out of the reach of children.
Disposal:
The unit must not be disposed of with normal household waste but
(in accordance with
must be disposed of in accordance with local environmental
directive 20002/96/EC)
regulations.
6. Maintenance
DANGER ! Electric shock !
➔ Pull out mains plug before undertaking any maintenance.
Clean suction filter:
1. The rotary switch
ቩ must be set to RUN.
If necessary turn the rotary switch
ቩ to RUN.
2. If necessary, close all the shut-off devices on the intake side.
3. Unscrew and remove cover
ቨ of the filter chamber.
4. Draw out filter unit
ቭ ቮ
vertically upwards.
5. Hold beaker
ቭ firmly, turn
filter
ቮ anti-clockwise A and
draw out B (bayonet fitting).
6. Clean beaker
ቭ under running
water and clean the filter
ቮ
e.g. with a soft brush.
7. Refit filter again in reverse
order.
©
ቩ
©
ቤ
©
ቩ
©
ቭ
©
ቪ
©
ቮ
©
ቨ
©
ቭ
©
ቮ
©
ቩ