beautypg.com

Operation – Gardena Pressure Tank Unit D-89070 Ulm User Manual

Page 5

background image

14

GB

Connect hose to the output side: Note:

Use pressure-tight hoses, such as the GARDENA Premium
Rubber hose of 19 mm (3/4”) diameter, Art. no. 4432/8452,
in connection with the GARDENA Quick-Release Threaded
Connector of 33.3 mm (G1) internal thread, Art. no. 7109,
and the GARDENA Suction and High Pressure Connector,
Art. no. 7120, for 19 mm (3/4”) hoses and a GARDENA Hose
Clip, Art. no. 7192.
Under no circumstances use these hoses on the suction side.

➔ Connect delivery hose ቧ to the delivery side connection.

4. Operation

Connecting the

DANGER ! Electric shock !

Pressure Tank Unit:

Before filling the pump, unplug the equipment

from the mains.

Warning ! Pump running dry.
Fill the pump to the overflow (approx. 2 to 3 litres)

with water each time before the pump is
switched on.

1. Unscrew the cover

ቨ of the filter chamber by hand.

2. Turn the rotary switch

ቩ to FILL.

The integrated non-return valve will open.

3. Open the air bleed

ቪ.

4. Open any shut-off devices in the delivery line (watering

accessories, water stop, etc.) so that air can escape before
the priming procedure begins.

5. Empty any water remaining in the delivery hose so that the air

can escape during filling and priming.

6. Slowly por approx 2 to 3 l of the liquid to be pumped throught

the filler neck

ቫ, until it emerges from the air bleed ቪ.

7. Screw the filter chamber cover

ቨ closed again, turning by

hand until it stops.

8. Close venting

and turn rotary switch to RUN.

9. Insert the mains plug into a 230 V mains socket.

CAUTION ! The pump will start immediately !

Once the maximum pressure is reached the pump will switch off
automatically. When the pressure falls below the minimum value
due to water being drawn off, the pump will switch on again
automatically.

The maximum self-priming head of 8 m is only achieved if the
pump is filled until it overflows via the filler connection

ቫ and the

delivery hose is held high enough so that no water can escape
via the delivery hose. It is not necessary to hold up the delivery
hose if filled suction hoses with backflow preventer are used.

©

©

©

©

©

©

©