ge.com

27" built-in double oven dimensions (in inches)
27" models PK956, JKP75, JKP55, JKP35

Oven support
for 27" models

E

Minimum
cutout location
from floor

Allow minimum of
21" for clearance
to adjacent corners,
drawers, walls, etc.

21

2" X 4" or
equiv. runners

Conduit

(48-1/2"

long)

Allow 3/4" for overlap
of oven over all
edges of cutout

10

A

D

Recommended
junction box
locations.
Locate junction
box either 5" MIN.
below cutout
floor or 48" MIN.
above cutout
floor

C

B

F

G

H

10

Locate
junction box
for 27"models

either 5" MIN.

below cutout
floor or 44"
MIN. above
cutout floor

Allow 3/4"
for overlap
over all edges
of cutout

A

Minimum
cutout location
from floor

D

E

2" X 4" or
equiv. runners
(cutout floor)

21" MIN.
door opening
allowance

B

C

H

F

G

Locate
junction box
for 24"models

56" MIN. above
cutout floor

Conduit

(48-1/2" Long)

21

27" built-in double ovens

(continued)

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

18"

over centerline

of cabinet

C

L

Suitable

bracing

to support

runners

18"

Over centerline

of cabinet

2" x 4" or

equivalent

runners

(Must support 300 lbs.)

(Must support 275 lbs.)

(Must support 275 lbs.)

Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at
least a 194°F temperature rating.
Note: If marks, blemishes or the cutout opening is visible above the installed oven,
it may be necessary to add wood shims under the runners and front trim until the
marks or openings are covered.
Note: Door handle protrudes 3" from door face. Cabinets and drawers on adjacent
45° and 90° walls should be placed to avoid interference with the handle.

Note: Door handle protrudes 3" from door face. Cabinets and drawers on adjacent
45° and 90° walls should be placed to avoid interference with the handle.
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at
least a 194°F temperature rating.
Note: If marks, blemishes or the cutout opening is visible above the installed oven,
it may be necessary to add wood shims under the runners and front trim until the
marks or openings are covered.

Installation information: Before installing, consult installation instructions
packed with product for current dimensional data.

Electric wall ovens are not approved for installation with a plug and receptacle.
They must be hard wired in accordance with installation instructions.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

11"

over centerline

of cabinet

Oven support
for 24" models

27" built-in microwave double oven dimensions (in inches)
Model JKP90

Cabinet

JPK956/JKP75/55/35

A – Cabinet width required

27" min.

B – Minimum cabinet depth

23-5/8"

C – Opening width

25" min. - 25-1/4" max.

D – Opening height

50-1/8" max.

E – Recommended minimum

cutout location from floor

13-1/4"

Oven

F – Overall depth*

23-5/8"

w/o trim

51"

G – Overall height with trim

51-7/8" - 52-3/4"

H – Overall width

26-5/8"

* Depth including door handle is approximately 26-7/10" min. to

26-8/10" max. on models PK956, JKP75/55/35.

Cabinet

27"

A – Cabinet width required

27" min.

B – Minimum cabinet depth

23-5/8"

C – Opening width

25" min. - 25-1/4" max.

D – Opening height

41-1/4" max.

E – Minimum cutout location from floor

22"

Oven

F – Overall depth*

23-5/8"

w/o trim

42-1/8"

G – Overall height

with trim

43" - 43-7/8"

H – Overall width

26-5/8"

* Depth including door handle is approximately 26-7/10" min. to 26-8/10" max.