27" built-in double ovens, Continued) – GE JKP75 User Manual
Page 2
ge.com
27" built-in double oven dimensions (in inches)
27" models PK956, JKP75, JKP55, JKP35
Oven support
for 27" models
E
Minimum
cutout location
from floor
Allow minimum of
21" for clearance
to adjacent corners,
drawers, walls, etc.
21
2" X 4" or
equiv. runners
Conduit
(48-1/2"
long)
Allow 3/4" for overlap
of oven over all
edges of cutout
10
A
D
Recommended
junction box
locations.
Locate junction
box either 5" MIN.
below cutout
floor or 48" MIN.
above cutout
floor
C
B
F
G
H
10
Locate
junction box
for 27"models
either 5" MIN.
below cutout
floor or 44"
MIN. above
cutout floor
Allow 3/4"
for overlap
over all edges
of cutout
A
Minimum
cutout location
from floor
D
E
2" X 4" or
equiv. runners
(cutout floor)
21" MIN.
door opening
allowance
B
C
H
F
G
Locate
junction box
for 24"models
56" MIN. above
cutout floor
Conduit
(48-1/2" Long)
21
27" built-in double ovens
(continued)
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
18"
over centerline
of cabinet
C
L
Suitable
bracing
to support
runners
18"
Over centerline
of cabinet
2" x 4" or
equivalent
runners
(Must support 300 lbs.)
(Must support 275 lbs.)
(Must support 275 lbs.)
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at
least a 194°F temperature rating.
Note: If marks, blemishes or the cutout opening is visible above the installed oven,
it may be necessary to add wood shims under the runners and front trim until the
marks or openings are covered.
Note: Door handle protrudes 3" from door face. Cabinets and drawers on adjacent
45° and 90° walls should be placed to avoid interference with the handle.
Note: Door handle protrudes 3" from door face. Cabinets and drawers on adjacent
45° and 90° walls should be placed to avoid interference with the handle.
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at
least a 194°F temperature rating.
Note: If marks, blemishes or the cutout opening is visible above the installed oven,
it may be necessary to add wood shims under the runners and front trim until the
marks or openings are covered.
Installation information: Before installing, consult installation instructions
packed with product for current dimensional data.
Electric wall ovens are not approved for installation with a plug and receptacle.
They must be hard wired in accordance with installation instructions.
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
11"
over centerline
of cabinet
Oven support
for 24" models
27" built-in microwave double oven dimensions (in inches)
Model JKP90
Cabinet
JPK956/JKP75/55/35
A – Cabinet width required
27" min.
B – Minimum cabinet depth
23-5/8"
C – Opening width
25" min. - 25-1/4" max.
D – Opening height
50-1/8" max.
E – Recommended minimum
cutout location from floor
13-1/4"
Oven
F – Overall depth*
23-5/8"
w/o trim
51"
G – Overall height with trim
51-7/8" - 52-3/4"
H – Overall width
26-5/8"
* Depth including door handle is approximately 26-7/10" min. to
26-8/10" max. on models PK956, JKP75/55/35.
Cabinet
27"
A – Cabinet width required
27" min.
B – Minimum cabinet depth
23-5/8"
C – Opening width
25" min. - 25-1/4" max.
D – Opening height
41-1/4" max.
E – Minimum cutout location from floor
22"
Oven
F – Overall depth*
23-5/8"
w/o trim
42-1/8"
G – Overall height
with trim
43" - 43-7/8"
H – Overall width
26-5/8"
* Depth including door handle is approximately 26-7/10" min. to 26-8/10" max.
47019_GE_57 57
47019_GE_57 57