1

PLUMBING

1. The cold water inlet is identified at the top of the heater (unless bottom

entry). The hot water connection is also identified at the top of the heater.

Install a shut-off valve in the cold line approximately 3’ from the inlet to

the heater where it is in convenient reach. This valve is for emergency

shut-off and MUST be kept open during the operation of the heater.

2. All nipples contain a plastic lining to minimize corrosion (cold inlet

nipples have double sleeve, hot outlet nipples have a single sleeve). Do

not apply heat to these nipples when making solder connections. Sweat a

piece of tubing to adapter before fitting adapter to nipple.

3. A combination Temperature and Pressure relief valve MUST be installed.

In some cases it is necessary that a Tee be fitted in the top of the heater

which allows the temperature probe to reach into the top of the tank. See

diagram on page 4. No shut-off valve of any kind is permitted between the

tank and the relief valve. The outlet of the relief valve must be piped to a

drain or fixture, and must terminate within 6” of the floor.

ELECTRICAL

1. Check to see that the element marking and nameplate data do correspond

with the electric service available.

a) The junction box where electrical connections are made is located near

the top of the heater, near the upper access door.

2. Install a circuit directly from the main fuse box. This circuit must be the

right size for the length of run and the load (see chart below).

RECOMMENDED FOR AMPERAGE

MAX. VOLTS

MAX.

WATTS

120V

208V

240V

1500

20A

10A

10A

3000

35A

20A

20A

3500

40A

20A

20A

4500

30A

25A

5500

35A

35A

The heater must be well grounded.

3. A ground wire must run from the green ground screw provided at the

electrical connection point in the heater junction box to the ground
connection at the service panel.

4. Adequate fusing must be provided at the service entrance as required by

local codes and/or electric utility having jurisdiction. This can be

accomplished with either a circuit breaker or fuse block in the service

panel or a separate disconnect switch, so that electric power can be shut

off easily when working on the heater.

5. Final connections are made at the junction box in the heater. Access to the

junction box is obtained by removing the cover near the knockouts.

6. The heater you have received is internally wired. A specific wiring

diagram is located inside the upper door or for certain models on the

rating plate. All wiring is color-coded and connections must be made as

shown in the wiring diagram

MAKE SURE HEATER IS COMPLETELY FILLED WITH WATER
BEFORE POWER IS TURNED ON. SEE ‘FILLING TANK’ SECTION.

WIRING

TWO WIRE CIRCUIT FOR NON-SIMULTANEOUS OPERATION.

SINGLE HIGH LIMIT.
The basic operation of a two thermostat system (upper and lower) on a

electric water heater of 240 volts is as follows:

Only one element will come on at any one time. This is known as a flip/flop

system. On a 240-volt water heater, there will always be 120 volts to both

elements. The thermostat will direct the second leg of the 120-volt to the

element to complete the 240 volts required for energizing the element.

Initial Start Up: When the tank is full of cold water, the upper thermostat

will take priority and the top portion of the water will heat up to the setting of

the thermostat. Once that temperature has been reached, the thermostat will

then flip down the 120 volts to the lower thermostat. The thermostat switch

closes and the bottom portion of the tank heats up until the water reaches the

setting on that thermostat. At this point the tank will be full of hot water.

Normal Operation: When hot water is being used, cold water enters the

bottom of the heater (either bottom feed or by diptube), and the bottom

element will begin to heat the cold water. If lots of hot water has been used,

the upper thermostat will take priority and the top portion of the heater will be

heated. Once heated, the thermostat will flip down to the lower thermostat to

heat the lower portion.