Action

1) Both “HI” and “XL” electrode circuits

open. Dual Level Control turns power on to

fill valve and keeps power off to thermostat.

2) “XL” electrode circuit closes. Power to

thermostat turned on. Power to fill valve

remains on.

3) “HI” electrode circuit closes. Dual Level

Control turns power off to fill valve and con-

tinues power to thermostat.

4) “HI” electrode circuit opens. “XL” circuit

stays closed. After a few seconds delay,

power to fill valve is turned on.

5) “XL” electrode circuit now opens. Power

to thermostat is turned off. Power to fill

valve remains on.

American Metal Ware 87710E Coffee Urn

Page 13

Fill Solenoid

Valve

Thermostat

Thermostat

Thermostat

Thermostat

ON

OFF

ON

ON

OFF

ON

ON

ON

Fill Solenoid

Valve

Fill Solenoid

Valve

Fill Solenoid

Valve

2. Description and Operation of Dual Level Control System (continued):

B.

3. Quick Service Check of Dual Level Control System:

1) All wire secure and properly connected.

2) Clean the electrodes. Lime (mineral scale) build-up can interfere with the

operation of any liquid level control system.

3) Check the common (ground) connection. A little looseness or dirt can cause

erratic operation.

Operation
Water Level
1) Below both electrodes

2) Rises to low electrode above

above heater coils

3) Rises to high electrode

4) Falls below high electrode only

5) Falls below low electrode.

(Same as condition no. 1)