beautypg.com

Engine wiring – Guardian Technologies 004583-0 User Manual

Page 30

background image

Section 8 — Electrical Data

Wiring Diagram, Portable Generator – Drawing No. 0G0731

ACTUATOR

ACTUATOR

GOVERNOR

GOVERNOR

4

0

CLOSEST TO BEARING

STATOR

30

30

85

85

87a

87a

86

86

87

87

SC

SC

BLACK

BLACK

12V

12V

BATTERY

BATTERY

SM

SM

RED

RED

SP2

SP2

SP1

SP1

IM2

IM2

FSS

FSS

LOP

LOP

D

D

IM1

IM1

STOP

STOP

RUN

RUN

(START)

(START)

0

IC

IC

PIN #

PIN #

12

12

11

11

10

10

8
9

7

6

SCR

SCR

5

4

3

0

2

1

F1

F1

GND

GND

SSR

SSR

ENGINE WIRING

ENGINE WIRING

30A

30A

C.B.

C.B.

22

22

C.B.

C.B.

30A

30A

0

22

22

22

22

G

0

0

TWISTLOK

TWISTLOK

120V/30A

120V/30A

WHITE

WHITE

22

22

0

0

G

WHITE

WHITE

TWISTLOK

TWISTLOK

120V/30A

120V/30A

20A

20A

C.B.

C.B.

C.B.

C.B.

20A

20A

C.B.

C.B.

30A

30A

30A

30A

C.B.

C.B.

LOAD

LOAD

LINE

LINE

WHITEW

H

I

T

E

HOTH

O

T

3

HOTH

O

T

1

WHITEW

H

I

T

E

0

5

4

2

HOTH

O

T

3

1

HOTH

O

T

DUPLEX

DUPLEX

120V/20A

120V/20A

120/240V

120/240V

30A TWISTLOK

30A TWISTLOK

WHITEW

H

I

T

E

0

4

5

WHITEW

H

I

T

E

2

WHITE

WHITE

120V/20A

120V/20A

GFCI

GFCI

X

Y

G

66

REGULATOR

VOLTAGE

12Vdc OUTLET

RESET BKR

10A AUTO

162

6

4

0

162

11S

22S

SCR - STARTER CONTACTOR RELAY

TB1, TB2 - TERMINAL BLOCK

SSR - START / STOP RELAY

SP2 - SPARK PLUG, CYL. 2

SP1 - SPARK PLUG, CYL. 1

SM - STARTER MOTOR

SC - STARTER CONTACTOR

R1 - 25 OHM, 25W RESISTOR

IM2 - IGNITION MODULE, CYL. 2

FSS - FUEL SHUT OFF SOLENOID

CB1 - 6AMP AUTO RESET BREAKER

LOP - LOW OIL PRESSURE

IM1 - IGNITION MODULE, CYL. 1

GND - GROUND BAR

F1 - 10A FUSE

D2 - 600V 12A DIODE

D - ENGINE SHUTDOWN DIODE

BA - BRUSH ASSEMBLY

LEGEND

RECTIFIER

CHARGE

BATTERY

CHARGE

BATTERY

RECTIFIER

D2

R1

22

ENGINE SHUTDOWN P.C.B.

ELECTRONIC GOVERNOR /

C.B.

C.B.

CONTROL

SWITCH

IDLE

ON/OFF

60A

60A

22S

55

11S

55A

TB2

TB1

BLK

CB1

BLK

RED

1

2

11

44

(50A/60A) OUTLET

(50A/60A) OUTLET

120/240V

120/240V

IDLE CONTROL
TRANSFORMERS

8

PIN #

12

10

11

9

BA

77A

5

7

6

66A

4

3

2

66

55

77

6

55A

22S

11S

22

77

50A/

50A/

4

0

77A

66A

77

66

6

55

2

55A

22S

11S

44

11

11

22

22

11

44

44

83

167
229

15B

0

86

86

15B

229

14

167

0

86

0

14

0

0

15

15

0

55A

55

0

14

18

18

14

14

44A

44A

11A

11A

44A

44A

11A

11A

11

11

44

44

22

22

44

44

44

44

44

44

11

11

11

11

11

11

11

11

44

44

11

11

44

44

44B

44B

44

44

11B

11B

11

11

22

22

0

0

22

22

22

22

11B

11B

0

11B

11B

0

0

0

44

44

44

44

0

11A

11A

0

0

0

0

0

0 0 0 55

55

0

0

0

13

13

15

15

16

16

17

17

14

14

13

13

14

14

17

17

15

15

86

86

167

167

0

15

15

18

18

0

15

15

15

15

0

0

15

15

15

15

0

44

44

11

11

11

11

44

44

11C

11C

11D

11D

44D

44D

44C

44C

44C

44C

11C

11C

11D

11D

44D

44D

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

0

22

22

0

14

14

14

14

13

13

9

10

10

12

12

5

1

2

6

4

8

18

18

15

15

0

0

14

14

86

86

15

15

16

16

0

15

15

13

13

167

167

0

18

18

15

15

86

86

17

17

14

14

13

13

13

13

16

16

13

13

17

17

83

167

229

15B

0

13A

15

15

15

15

55A

55

0

14

66A

77A

4

66

77A

4

0

66A

6

77

0

15A

13A

0

0

0

0

15A

0

14

0

14

14

14

162

55

55A

-

+

J1

J2

OFF

OFF

ON

ON

GREEN

GREEN

WHITE

WHITE

X

Y

22

22

11

11

44

44

15B

15B

229

229

14

14

167

167

0

86

86

0

0

15

15

15

15

0

55A

55A

55

55

0

14

14

28