beautypg.com

Installation instructions, Run wires, Cut holes – GE Monogram JN327 User Manual

Page 12: Mark holes, C. outside rear exhaust (horizontal duct–3, X 10, Rectangular), A. outside top exhaust (vertical duct–3, B.outside top exhaust (vertical duct–7, Round)

background image

12

D. Recirculating (non-vented ductless–

JN327 and RN328, and optional on
JV347 and JV367 models only)

Use the hood as a template and mark the locations

on the cabinet for the electrical wiring and keyhole
screw slots.

Since the hood is to be recirculated (not to be vented

outside), do not cut out any vent openings in the wall
or cabinet bottom.

Installation Instructions

Wood shims

(recessed-bottom cabinets only–shims must be a
minimum of 3/8

thick and cut to fit the width

of the inner recessed cabinet bottom)

Cabinet front

Center line

Electrical access hole

(in wall)

Hood mounting screws (4)

Horizontal duct
access hole

Cabinet
bottom

13

3

4

″ (30″ hood)

16

3

4

″ (36″ hood)

1

1

4

1

2

3

3

4

5

1

4

5

1

4

7

3

4

13

3

4

″ (30″ hood)

16

3

4

″ (36″ hood)

C. Outside rear exhaust

(Horizontal duct–3

1

4

x 10

Rectangular)

Use the diagram or the hood as a template and

mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.

RUN WIRES

Run the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE:

DO NOT turn the power on until

installation is complete.

13

CUT HOLES

Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4

″ extra

toward the front of the cabinet so you can move the
duct freely when installing the hood. It may also ease
installation by cutting the hole 10

1

2

″ instead of 10″.

12

MARK HOLES

Select the vent option that your installation will
require and proceed to that section:

Hood mounting screws (4)

13

3

4

″ (30″ hood)

16

3

4

″ (36″ hood)

13

3

4

″ (30″ hood)

16

3

4

″ (36″ hood)

Cabinet front

Center

line

Electrical access hole
(in cabinet bottom)

Wood shims

(recessed-bottom cabinets
only–shims must be a
minimum of 3/8

thick

and cut to fit the width
of the inner recessed
cabinet bottom)

Vertical duct

access hole

9

5

8

1

3

8

1

1

4

7

3

4

3

3

4

1

2

A. Outside top exhaust

(Vertical duct–3

1

4

x 10

Rectangular)

Use the diagram or the hood as a template and

mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.

B.Outside top exhaust (Vertical duct–7

Round)

Use the diagram or the hood as a template and

mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.

Hood mounting screws (4)

13

3

4

″ (30″ hood)

16

3

4

″ (36″ hood)

13

3

4

″ (30″ hood)

16

3

4

″ (36″ hood)

Cabinet front

Center

line

Electrical access
hole

(in cabinet bottom)

Wood shims

(recessed-bottom cabinets
only–shims must be a minimum
of 3/8

thick and cut to fit the

width of the inner recessed
cabinet bottom)

Access
hole for 7

round duct

9

5

8

1

3

8

1

1

4

7

3

4

5

3

4

Cabinet
bottom

8

DIA.

HOLE

Cabinet Bottom

11

5

1

4

5

1

4

This manual is related to the following products: