Thermal Relay Overload

Amp Adjustment Dial:

Turn this dial to meet your

motor manufacturer's

thermal overload amp setting

specification. Typically this

setting is 100-110% of what is

listed on the motor data plate as

the max amp load. Remember,

turning this dial has no effect on

increasing motor horsepower.

If this dial is turned to an amp

setting that is too high, the

motor can overheat and be

damaged before the relay

trips.

Trip Indicator: If the window

is flagged yellow, the thermal

relay has tripped.

Manual Trip Test Lever:

If the thermal relay function

is in question, use a wooden

toothpick to slide the yellow test

lever to the left. If the motor

shuts off, the thermal relay has

tripped and is functional.

ON Button:

When pushed, power is sent
to the magnetic field coil and
the contactor closes and
sends power to the motor.

Manual/Auto Reset Lever:

In the up position, the
thermal relay is in manual
reset mode, where if tripped,
you must first push the
red and then the green
ON button reset button
on the outside of the main
cover to reset the thermal
relay. In the down position,
the thermal relay will
automatically reset when it
has cooled.

Reset Button:

When pushed, the thermal
relay is reset and the
yellow flag shown in the trip
indicator window is cleared.

Manual Contactor Override Lug:

When pushed, the contactor is

manually closed for troubleshooting

purposes only.

OFF Button:

When pushed, the current going to the magnetic field coil is cut, which

opens the contactor and cuts power to the motor.

Parts Breakdown

REF PART #

DESCRIPTION

REF PART #

DESCRIPTION

1

P4571001

SWITCH BOX

6

P4571006

CONTACTOR RETAINER

2

P4571002

SWITCH BOX COVER ASSEMBLY

7

PS55M

PHLP HD SCR M3-.5 X 10

2-1

P8294002-1

DATA LABEL, HNFB-16KK

8

P4571008

CAPTURED GROUND SCR M4-.7 X 10

3

P8293003

CONTACTOR TECO CN-16 440V

9

PS10

PHLP HD SCR 10-24 X 1-1/2

4

P4571004

FIELD SWITCH TECO CNA-1

10

P4571010

LIQUID-TITE STRAIN RELIEF

5

P8294005

RELAY TECO RHN-10K 5.5-8.5A

11

P4571011

RUBBER SEAL

11

10

9

5

2

4

6

7

8

1

3

2-1