Installation instructions, Remote control/wall thermostat (class 2), Central desk control (load shedding) – GE ZONELINE 3200 User Manual

Page 18: All-time low fan

background image

Installation Instructions

To operate the Remote Control/Wall
Thermostat (Class 2) switch #3, you must use
an Optional Interface Module kit. See the
Installation Instructions with accessory kit
RAK0IM.

UP

DOWN

1 2 3 4 5 6

Remote Control/Wall Thermostat (Class 2)

To operate Central Desk Control (CDC),
switch #5, you must have an Optional Interface
Module kit. See the Installation Instructions with
accessory kit RAK0IM.

UP

DOWN

1 2 3 4 5 6

Central Desk Control (Load Shedding)

Switch #4 controls the All-Time Low Fan and is
only effective with a Remote Control Thermostat.
This function causes the indoor fan to operate at
low speed. If the switch is

DOWN

(off) the fan will

run in high speed. If the switch is

UP

(on) the fan

will run in low speed.

UP

DOWN

1 2 3 4 5 6

All-Time Low Fan

18

Auxiliary Controls