4-Wire Conduit Installation

Remove the 3 screws from the connector block.

Remove the grounding strap from the connector

block middle location and the screw connecting it to

the frame of the range. Insert bare wires between

the connector block terminals and movable nuts.

Tighten screws securely. Attach ground wire to the

frame of the range

.

WARNING: Connector block is approved for
copper wire connection only. If aluminum wire
is used, see note below.

NOTE: ALUMINUM WIRING

A.

Do not connect aluminum wire to connector

block.
Use copper building wire rated for the correct

amperage and voltage to make three 3

copper

jumper wires. Connect wire as per Step 6 or 7

depending on number of wires.

B.

Splice copper wires to aluminum wiring

using special connector terminals designed

and UL-approved for joining copper to

aluminum and follow the connector

manufacturer’s recommended procedure

closely.

Wire used, location and enclosure of splices, etc., must
conform to good wiring practices and local codes.