beautypg.com

Connect the range to gas, Checking manifold gas pressure – GE 164D3333P185-1 User Manual

Page 29

background image

Safety Instructions

Operating Instructions

Care and Cleaning

Installation Instructions

Troubleshooting T

ips

Customer Service

Read these instructions completely and carefully.

Connect the Range to Gas

The house piping and connector used to connect the range to the main gas supply must be
clean, free of metal shavings, rust, dirt or liquids (oil or water). Contaminants in the supply lines
can work their way into the range manifold and cause failure of gas valves or controls and clog
burners or pilot orifices.

If the range is to be connected to house

piping with flexible or semi-rigid metal

appliance connector, connector nuts MUST
NOT

be connected directly to pipe threads.

The appliance connector must be installed

by using the proper flare union adapters with

the connector. Cutoff valve, appliance

connector and adapters are not supplied

with the range. (Because solid pipe restricts

moving the range, we recommend use of

A.G.A. certified flexible tubing.) In Canada,

flexible connectors must be single wall metal

connectors no longer than 6 feet in length.
Install a manual shutoff valve in the gas line

in an easily accessible location outside of the

range. Be sure you know how and where to

shut off the gas supply to the range.
Check for leaks. After connecting the range

to gas, check the system for leaks with a liquid

leak detector at all joints and connections.

Tighten all connections as necessary to

prevent gas leakage in the range or supply

line.

CAUTION: Do not use a flame to check for
gas leaks.

Check alignment of valves after connecting

the range to the gas supply to be sure the

manifold pipe has not been moved. A

misalignment could cause the valve knob

stem to rub on the control panel, resulting in

a gas leak at the valve.

Disconnect the range and its individual shut-off

valve from the gas supply piping system during

any pressure testing of the system at test pressures

greater than 1/2 psig.
Isolate the range from the gas supply piping

system by closing its individual manual shut-off

valve during any pressure testing of the gas supply

piping system at test pressures equal to or less

than 1/2 psig.

29

House
piping

Flare union

adapter

Flare union

adapter

Range pressure

regulator

Appliance
connector

Nut

Nut

Checking Manifold Gas Pressure

If it should be necessary to check the manifold gas

pressure, connect manometer (water gauge) or

other pressure device to the top burner orifice

farthest from the manifold inlet and turn burner

valve on.
For an accurate pressure check have at least

2 other top burners burning. Be sure the gas

supply inlet pressure is at least one inch above

specified range manifold pressure.

The gas supply pressure should never be over

14 inches W.C. When properly adjusted for

Natural Gas the W.C. pressure is 4 inches; for LP

Gas the W.C. pressure is 10 inches. The serial

plate, located under the main top in the burner

box area, indicates for which type of gas your

range was factory adjusted.