GSI Outdoors PNEG-951 User Manual
Page 25
25
PNEG-951
View MR Speed Average
On this screen is information showing you how much time the metering roll system has spent on HI speed
and LOW speed. The ideal values of course is at 50% each, although in real world situations this is very
difficult to obtain. Having a 30% - 70% reading is not uncommon but anything over this may indicate that
meter roll speed settings may need adjusting. This can vary throughout the day due to a number of condi-
tions including drying wetter grain or ambient temperature changes of 10
8 or more.
Reset MR Average
Press the
button and move the pointer to change your selection to Reset MR Average
and press the
button.
You can reset the speed average by pressing the
button or you can exit out of this function by
pressing the
button and goto the User Hour Meter screens.
User Hour Meter
The User Hour Meter is a custom timer which can be used for several different scenarios. For instance, if you
wanted to monitor the amount of time used between different hybrids of corn or if you have more then one user of
the dryer.
Press the
button to exit back to the main drying screen.
Reset User Hour Meter
Pressing the
button at this point will cause the to be reset back to 0.
If this is not the desire action then press the
button to exit back to the main drying screen.