beautypg.com

Grandstream Networks GXV300X User Manual

Page 28

background image

Grandstream Networks, Inc.

GXV300x User Manual

Page 26 of 54

Firmware 1.2.3.7

Updated: 12/2010

Disable SIP User Display

Default is No. If enabled, SIP User ID will not be shown on the LCD

Disable IP Address Display Default is No. If enabled, the IP address of the phone will not be shown on the LCD

LCD Screen Saver
Start Interval

Default value is 60 seconds, 0 means turn off this feature.
After 60 seconds the Screen Saver will start. The Screen saver file stored in flash is limited to
20 images or 320kb. Change screen saver in the same way as customized ring tone.

LCD Screen Saver
Refresh Interval

Default is 10.
This parameter controls the picture changing speed showed on the LCD.

LCD Auto Power Off
Interval

Default value is 300 seconds. 0 means LCD is always ON
After 300 seconds of idle time, the LCD will automatically Power Off.

LCD Backlight Brightness

Default value is 128.

LCD Contrast

Default value is 128

LCD Chroma Saturation

Default value is 128

LCD Text Color

Change the LCD font text color, adjust via selected numbers. Default is 255

OSD Text Color

Select desired OSD (On Screen Display) Text color from drop down box.
Default is white. The color can distinguish OSD from video background

PIP Position

Local Mirror Images showed via Picture in Picture positions in the LCD. Default is Top Left.

Starting Video OSD/PIP
Mode

Default value is OSD On, PIP On

Camera Zoom Mode

Select desired camera zoom mode (Wide, Optical Tele, Digital Tele). Can adjust local video
zoom either in mirror mode or during the call (on the fly) by pressing the Left or Right Arrow
Key

Camera Exposure

Select desired Camera Exposure mode based on surroundings. Default to Auto

Camera Color Mode

Select desired Camera Color Mode (Color or Monochromatic). Default to Color Mode

Camera White Balance

Select desired Camera White Balance to be automatic or Fixed. Default to Auto

Camera Lens Correction

Correct Camera Lens noise. Default is Yes.
Recommend set to YES to reduce camera lens noise and improve video quality.

TV Output

Select desired TV Output type (PAL or NTSC).




A

DVANCED

U

SER

C

ONFIGURATION


The Advanced User configuration includes not only the end user configuration, but also advanced confi-
guration such as SIP configuration, Codec selection, NAT Traversal Setting and other miscellaneous con-
figuration.

Login to the Advanced User Configuration page following the same directions as in Basic Configuration.
The factory default password for Advanced User is “admin”. User may change the password. The pass-
word is case sensitive with a maximum length of 25 characters.