beautypg.com

Generac Power Systems 005223-0 User Manual

Page 47

background image

1

033212

4

SCREW HHC 5/16-18 X 1-1/4 G5

2

075580

1

FLANGE FUEL INLET

3

0F6390

1

REGULATOR ASSEMBLY DUAL FUEL

4

039253

2

SCREW HHC M8-1.25 X 20 G8.8

5

022145

2

WASHER FLAT 5/16-M8 ZINC

6

022129

6

WASHER LOCK M8-5/16

7

045771

2

NUT HEX M8-1.25 G8 CLEAR ZINC

9

0E8286

1

STREET EL 45 DEG 1/2" NPT BRASS

10

026812

2

ELBOW 90D 3/4 NPT

11

0F8379

1

NIPPLE PIPE 3/4 NPT X 7”

12

0F3869

1 (REF.)

SWITCH PRESSURE GAS 5" RISE (INCLUDED WITH I/N 3)

13

057823

2

CLAMP HOSE #10 .56-1.06

14

059194

1

HOSE 5/8 ID LPG & NG (31.5” LG)

15

064945

1

GASKET CARB ADAPTOR

16

0D1509

1

DECAL INLET PRESSURE

17 *

050279

1

DECAL FUEL INLET NG (NATURAL GAS APPLICATION)

050280

1

DECAL FUEL INLET LPG (LP VAPOR APPLICATION)

18

0E7839

1

MACHINING CARBURETOR ADAPTOR

19

0E6586

1

GASKET BOSCH 32 & 40

20

0E4394

1

ACTUATOR BOSCH 40 GOVERNOR

21

040105

1

HOSE COOL 2IN ID 20R4 (2” LG)

22

0E6382B

1 (REF)

VENTURI HOLDER W/40MM ACTUATOR

23

0E7121

1 (REF)

O-RING 47.625 ID X 2.38 WIDTH

24

0E6376B

1 (REF)

VENTURI 28 ID THROTTLE W/CHOKE

25

042561

2

CLAMP HOSE #36 1.88-2.75

26

0E9295

1

ASSY THROTTLE 28MM

27

061012

1

PLUG STD PIPE 1/8 SOCKET HEAD

28

022097

4

WASHER LOCK M6-1/4

29

044118

1

BARBED STR 1/2 NPT X 5/8

30

046580

4

SCREW SHC M6-1.0 X 45 G12.9

31

026915

2

NIPPLE CLOSE 3/4 X 1.375

33

0F6155

1

HARNESS CPL FUEL JUMPER

NOTES:
1.

REGULATOR (I/N 3) AS SHOWN IN ILLUSTRATION IS SET UP FOR
NATURAL GAS APPLICATION.

2.

TO CONFIGURE REGULATOR FOR LP VAPOR, SWITCH HOSE BARB,
HOSE CLAMP (I/N 13) AND HOSE (I/N 14) FROM “OUT-1” TO “OUT-2”.

REPLACE PIPE PLUG FROM “OUT-2” TO “OUT-1”. USE PIPE SEALANT
ON HOSE BARB AND PIPE PLUG. MAKE SURE TO KEEP PORTS FREE
FROM DEBRIS DURING RECONFIGURATION PROCESS.

3*. FOR LP VAPOR APPLICATION SUBSTITUE LPG FUEL INLET DECAL P/N
050280 FOR NG FUEL INLET DECAL P/N 050279 (ITEM17).
4 . WHEN SWITCHING FUEL TYPES, THE PROPER DIP SWITCH SITTINGS
MUST BE MADE TO THE CONTROL PANEL. SEE OWNERS MANUAL, FUEL
SECTION FOR MORE DETAILS.