3-WIRE INSTALLATION

WARNING:

The neutral or ground wire of the power cord must be connected

to the neutral terminal located in the center of the terminal block. Ground strap must connect
the neutral teminal to the ground plate. The power leads must be connected to the lower
left and the lower right terminals of the terminal block.

DO NOT remove the ground strap connection.

FOR POWER CORD INSTALLATION

A. Remove the 3 lower terminal screws from the terminal block.

B. Insert the 3 terminal screws through each power cord termi-

nal ring and into the lower terminals of the terminal block. Be
certain that the center wire (white/neutral)
is connected to the center lower position of the terminal
block.

C. Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A. Loosen the 3 lower terminal screws from the terminal block.

B. Strip wire to expose tip about 5/8" long. Insert the center

(white/neutral) wire tip through the bottom center terminal block opening. On
certain models, the wire will need to be inserted
through the ground strap opening and then into the bottom
center block opening. Insert the two side bare wire tips into
the lower left and the lower right terminal block openings.

C. Tighten screws until the wire is firmly secured (35 to 50 inch-lbs.).

Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: Aluminum building wire may
be used but it must be rated for the correct amperage and voltage.

PROCEED TO STEP 9.

7

Ground
strap

Terminal block
(appearance
may vary)

Neutral
terminal

Power cord

Ground
plate

Power Cord

4-WIRE INSTALLATION

WARNING:

The neutral wire of the supply

circuit must be connected to the neutral terminal
located in the lower center of the terminal block.
The power leads must be connected to the lower
left and the lower right terminals of the terminal block.
The grounding lead must be connected to the frame
of the range with the ground plate and the green
ground screw.

FOR POWER CORD INSTALLATION

A. Remove the 3 lower terminal screws from

the terminal block. Remove the ground screw
and ground plate and retain them. Cut and discard
the ground strap. DO NOT DISCARD ANY SCREWS.

B. Insert the one ground screw into the power cord ground

wire terminal ring, through the ground plate and into
the frame of the range.

C. Insert the 3 terminal screws (removed earlier) through

each power cord terminal ring and into the lower terminals
of the terminal block. Be certain that the center wire
(white/neutral) is connected to the center lower position
of the terminal block. Tighten screws securely into
the terminal block.

FOR CONDUIT INSTALLATION

A. Loosen the 3 lower terminal screws from the terminal block.

Remove the ground screw and ground plate and retain
them. Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.

B. Strip the wire to expose tip about 5/8" long. Insert

the ground bare wire tip between the range frame
and the ground plate (removed earlier) and secure
it in place with the ground screw (removed earlier).
Insert the bare wire (white/neutral) tip through the bottom
center of the terminal block opening. Insert the two
side bare wire tips into the lower left and the lower
right terminal block openings.

C. Tighten the screws until the wire is firmly secured

(35 to 50 inch-lbs.). Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated
for the correct amperage and voltage.

8

Before–Power Cord and Conduit

Terminal
block

Terminal
block

Neutral termi-
nal

Neutral
terminal

Ground
strap

Ground plate
(grounding to
range)

Ground
screw

Ground strap

or

After–Conduit

Terminal
block

Ground
plate
(grounding
to range)

Wire
tips

Ground screw

After–Power Cord

REPLACE THE WIRE COVER

Replace wire cover on range back by sliding its left edge under
the retaining tabs and replace the screws removed earlier. Make sure
that no wires are pinched between cover and range back.

9

POWER CORD AND CONDUIT INSTALLATION (CONT.)

C. For power cord installations only (see the next

step if using conduit), assemble the strain relief
in the hole. Insert the power cord through the strain
relief and tighten. Allow enough slack to easily
attach the cord terminals to the terminal block.
If tabs are present at the end of the winged
strain relief, they can be removed for a better fit.
NOTE: Do not install the power cord without a
strain relief. The strain relief bracket MUST be
installed before reinstalling the rear range wiring
cover.

D. For conduit installations only, purchase a squeeze

connector matching the diameter of your conduit and
assemble it in the hole. Insert the conduit through the
squeeze connector and tighten. Allow enough slack to eas-
ily attach the wires to the terminal block.
NOTE: Do not install the conduit without a squeeze con-
nector. The squeeze connector MUST be installed
before reinstalling the rear range wiring cover.

6

Power cord

Strain relief

Terminal
block

Bracket

Squeeze connector

Terminal
block

Bracket

Wire
cover

Wire tips

Terminal
block

Conduit

Conduit