beautypg.com

Servicing instructions, Replacing parts, Primary aeration plate – Stovax Ceramica Gazco Ceremica Log Effect Stove Range User Manual

Page 21: Changing between gas types

background image

21

SERVICING INSTRUCTIONS

REPLACING PARTS

9.5 Refit the new sensor, ensuring that the plastic spacers are

between the sensor and the bracket. Refit the leads. See

Diagram 20.

9.6 Feed the cable back through the hole as you replace the

bracket. When the bracket is located correctly it will sit

flush with the back panel without force required. If not

positioned correctly the bracket will sit at an angle. See

Diagram 21.

10. PRIMARY AERATION PLATE

10.1 Turn the gas supply off at the isolation device.
10.2 Refer to Section 2 to remove the main burner.
10.3 Remove the two screws on the burner skin to detach the

venturi cover from the venturi. Slide the venturi cover off the

venturi as per diagram 22.

10.4 Change the aeration plates to those stated in the technical

specification for the gas the product will be using, refer to

the databadge.

NOTE: EVEN IF NO AERATION PLATE IS REQUIRED, THE

SMALL SCREW MUST BE REPLACED.

11. CHANGING BETWEEN GAS TYPES

In order to change between gas types, it will be necessary to

change the following items.
- Pilot Injector
- Control Valve
- Main Injector
- Main Burner
- Aeration Plate (if required)
- Databadge
The relevant parts can be ordered from Gazco, always quote

the appliance type and serial number when ordering spare

parts.

** NOTE: THE CONTROL VALVE IS FACTORY PRESET

FOR CORRECT GAS TYPE AND MODEL, A NEW UNIT

WILL NEED TO BE ORDERED WHEN CHANGING

BETWEEN GAS TYPES.

AR0619

23

AR1608

22

AR1452

20

AR1447

AR1448

21