Field Controls UV-16/24 User Manual
Page 3
page 3
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire
™
Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
INSTALLATION
Locate a suitable location for the unit downstream from the 'A' coil in
1.
the supply plenum or in the return plenum; preferably downstream from
the air filter. For optimum "cleaning" effect on the 'A' coil, mount the
unit in the supply plenum as close as possible to the 'A' coil.
(See Figure 1)
CAUTION:
Investigate and determine the location of the A coil prior to
drilling holes in duct for mounting unit.
NOTE:
For duct board installation, refer to enclosed bagged assembly
containing mounting plate and instructions.
Apply supplied mounting template to air duct in either
2.
a vertical or horizontal position. (See Figure 2) Leave
template mounted to duct for future reference.
Drill
3.
1
⁄
8
" diameter mounting holes at positions indicated
on template. (See Figure 3)
Cut out the large opening (1-
4.
1
⁄
2
" hole) on the template.
(See Figure 3)
Using a
5.
1
⁄
4
" to
1
⁄
2
" drill bit, drill a viewport hole as
indicated on the template. (Figure 3)
Optional Light Shield: The light shield may be mounted
6.
at virtually any angle. However, when deciding on a
suitable location, the mounting screw head can not be in
the shaded area of template. (See Figure 4 to view areas
to avoid.)
Figure 1
Figure 3
Figure 2
Figure 4
Head of mounting screw CANNOT be
located in shaded area.
Notes:
For applications with multiple systems, we recommend one unit
•
per system.
For larger applications, multiple units are recommended.
•
Contact technical support at 1-252-522-3031 for sizing.
Each unit will require its own transformer.
•
Square Footage
UV-Aire
(For ducts at least 16" wide) Volts Watts Amps Hz
Up to 2000
1
24
23
1.3
60
4000
2
24
46
2.6
60
SIZING AND SELECTING UNITS
See chart below: